Satisloh Multi-Flex

Satisloh Multi-Flex

Important settings for the Multi-Flex within Rx-Universe

 

  1. In the Blank Selection tab under system settings in Rx-Universe make sure the “Blank size force allowance” is set “0”

image-20240205-161124.png
  1. In the Surf1 tab under system settings in Rx-Universe make sure the “Crib safety allowance” is set to “4”.

image-20240205-162531.png

 

You can also set up the “Min Edge Thickness at Crib” as a default system settings, based on lens style or by passing the information to the digital calculator if accepted. This is help avoid knife edge on lenses.

 

System Settings:

In the Surf1 tab under system settings

Lens Style:

Digital Calculator:

For the digital calculator, Rx-Universe would need to send MINTHKCD

There was some improvement made to those calculation after version 7.62.00. Always run the latest and greatest update version.