Redo Code Setup & Process (using Tray Tracking Stations)
Search Optifacts User Documentation
Table of Contents (on this page)
Introduction
This document provides instructions for defining Redo Codes using Tray Track Stations. When a job is entered or relaunched from the archive, use Redo Reasons for warranty, non-adapt, or other reasons. Use Redo Reasons in reporting to track redo activity by the lab and the reason.
There is an alternative procedure for setting up Redo Reasons using Job Data Definitions, Triggers and Reasons. Refer to the Redo Reasons Setup & Process (using Job Data Definitions, Triggers, and Reasons) document for full instructions.
Procedure
The setup for Redo Reasons using tray track stations is a multi-step process.
Step 1 - Verify that the Lite-ups exist.
The lite-ups that you create get used as the descriptions for the tray tracking master stations.
From the Optifacts main menu:
Select Option 11 - Retail Transfer and press Enter.
Select Option 14 - Report: Pricing Options Available and press Enter.
The report will display on the screen.
- Scroll down using the page down or the down arrow key on your keyboard until you find the Redo lite-ups. (The report sorts alphabetically)
If you do not see the lite-ups, you need to create them as follows:
Add/Edit Lite-up Options
From the Optifacts main menu:
Select Option 3 - Editor Utilities and press Enter.
Select Option 4 - Pricing Database Editor and press Enter.
Select Option 4 - Lite-up Options and press Enter.
Select Option 1 - Add/Edit Lite-up Options and press Enter.
The Add/Edit Lite-up Options screen displays.
- Valid for (G) Glass, (P) Plastic,or ( * ) Both
- Enter an ( * ) asterisk for both.
- Enter the lite-up number that you are going to use and press Enter.
The screen will expand and display the rest of the fields.
Enter all the data as shown in the following diagrams pressing Enter past each field. Refer to the Add/Edit Lite-up Options document for full instructions. We are using Lab Redo as an example but you will need lite-ups for each Tray Track Master Station as described in Step 4 of this document.
Are the Entries Correct (Y/N)?
- Press “Y” if correct and press Enter
- Press “N” to return to the form.
Example:
Step 2 - Set up the Job Data Definition
Refer to the Defining Job Data Definition Fields with Examples document for full details on each field. We will show you some examples below. However, your lab may have set up other redo reasons that would need set up using the same process described below.
From the Optifacts main menu:
Select Option 3 - Editor Utilities and press Enter.
Select Option 6 - Configuration Editor and press Enter.
Select Option 7 - Edit Job Data Definitions and press Enter.
The Prompt Configuration for Miscellaneous Job-Related Data window displays.
- Press “A” to add a new record.
- Enter all the applicable data as per the diagrams below, pressing Enter past each field.
The Field Name should be entered exactly as the Lite-up Description created in the step above.
The Include or Limit field values are the tracking station numbers assigned to the reasons. In the Lab Redo example below: the tracking station number range is 801 to 832.
Press Escape to save the data.
Press "E" to exit the screen.
Examples:
Lab Redo
Dr. Redo
Non-Adapt Redo
Warranty Redo
Warranty Card
You may also need to set up Warranty Card Info.
Step 3 - Set up the Job Data Trigger
Refer to the Defining Job Data Triggers document for full details on each field. We will show you some examples below. However, your lab may have set up other redo reasons that would need set up using the same process described below.
From the Optifacts main menu:
Select Option 3 - Editor Utilities and press Enter.
Select Option 6 - Configuration Editor and press Enter.
Select Option 8 - Edit Job Data Triggers and press Enter.
The Triggers to Cause Prompts for Miscellaneous Job-Related Data window displays.
- Press “A” to add a new record.
- Enter all the applicable data as per the diagrams below, pressing Enter past each field.
You will need to add entries for each of the lite-ups you created in step 1, and the Field Name must match the lite-up name exactly. You need to know the num and bit for each lite-up. Run the Pricing Options Available report in menu 11-14 to find the num and bit for each applicable lite-up.
You must enter the num and bit as shown on the Pricing Options Available report.
Press Escape to save the data.
Press "E" to exit the screen.
Examples:
Lab Redo
Dr. Redo
Non-Adapt Redo
Warranty
Step 4 - Set up the Master Tray Tracking Stations
From the Optifacts main menu:
Select Option 7 - Tray Track and press Enter.
Select Option 12 - Tray Track Configuration and press Enter.
Select Option 1 - Master Station Number Setup and press Enter.
The Master Station Number Setup screen displays.
- Press “Q” to query.
Search for the master station numbers or descriptions as determined by your system administrator.
- Enter the predetermined number in the master station number field.
- Press Escape to show the results.
If the entries exist, they should look like the examples below. Of course, your lab may choose to have more than just these examples set up.
- If the entries do not exist, Press “A” to add
- Enter all the applicable data as per the examples below, pressing Enter past each field.
- Press escape to save the data.
- Press “E” to exit the screen.
Examples:
Lab Redo
Dr. Redo
Non Adapt
Warranty
Step 5 - Set up the Sub-Master Tray Tracking Stations
From the Optifacts main menu:
Select Option 7 - Tray Track and press Enter.
Select Option 12 - Tray Track Configuration and press Enter.
Select Option 2 - Sub-Master Station Number Setup and press Enter.
The Sub-Master Station Number Setup screen is displayed.
- Press “Q” to query.
Search for the sub-master station numbers or descriptions as determined by your system administrator.
- Enter the predetermined number in the master station number field, or Enter the predetermined number or description in the appropriate fields.
- Press Escape to show the results.
If the entries exist, they should look like the examples below. Your lab should have many more sub-master stations for defining redo codes than just these examples shown below.
The station type is Y.
- If the entries do not exist, Press “A” to add
- Enter all the applicable data as per the examples below, pressing Enter past each field.
- Press Escape to save the data.
- Press “E” to exit the screen.
Examples:
Lab Redo Code
Dr. Redo Code
Non-Adapt Code
Warranty Code
Step 6 - Job-Related Job Data Screen
You may already have this set up for other processes. It is required for order entry to be able to enter the redo codes.
If not set up, you will have to set it up as follows:
From the Optifacts main menu:
Select Option 7 - Tray Track and press Enter.
Select Option 12 - Tray Track Configuration and press Enter.
Select Option 2 - Sub-Master Station Number Setup and press Enter.
The Sub-Master Station Number Setup screen is displayed.
- Press “Q” to query.
Search for the station description “JOB DATA ENTRY’.
- Enter “JOB DATA ENTRY’ in the station description field.
- Press escape to show the results.
If the entry exists, it should look like the example below.
- If the entry does not exist, Press “A” to add a record.
- Enter all the applicable data as per the examples below, pressing Enter past each field.
Use the Master and Sub-master station numbers as predetermined by your system administrator.
Press Escape to save the data.
Press "E" to exit the screen.
Order Entry Redo Process
The following diagrams show the selections that the order entry operator would need to make using the above examples.
From the Pricing Options screen in order entry, they would need to choose the lite-up applicable to the type of Redo. In our example, we are using lite-up #77 Lab Redo.
The operator would continue to enter the order until they reached the following screen.
Job-Related Job Data Entry Screen
There may be additional job data shown on this screen depending on the type of job and setup
Press "C" to continue
Enter the applicable Redo Code and press Enter.
If you enter an invalid code, it will tell you the range that is permitted.
- Enter the correct code.
The order gets submitted for calculation.
To view and download these instructions as a PDF file, click on the following document image.
Did you know?...
Optifacts is now utilizing a help-desk ticket system to better serve your emailed support needs and have your requests assigned to a team member that can support you best.
Please consider emailing your support requests to support@optifacts.com rather than individual addresses for more efficient support.
You may also log in to your account at https://rxuniverse.atlassian.net/servicedesk/customer/portal/12 to submit your requests directly and see the status of any currently open tickets your lab may have.
If you are in need of immediate support, please call the support desk directly at (800) 678-4322 during business hours of 8 am to 5 pm CST/CDT, Monday through Friday.
Optifacts, Inc. Suite 100 - 18 Riverside Ave. S. Sartell MN 56377
Phone: (800) 378-4322 Phone: (320) 258-3559 Fax: (320) 258-3880
Email: sales@olsssystems.com Email: support@optifacts.com
Optifacts Service Desk: http://support.optifacts.com
Click Here to Find Out More About Us