ART / Nucleo Blocking
ART and Nucleo Blocking
When using ART or Nucleo blocking, the rules for block selection are different, and the same constraints applied to traditional blocking do not apply. The physical diameter of the block may not restrict the crib diameter if the block can be cribbed at the generator.
ART and Nucleo blocks are available in several different different base curves, and must be selected correctly to ensure the proper amount of adhesive is used between the block and the blank. In addition, since the blocks can be re-used after cribbing, blocks must be selected based on how much block is left (the effective diameter of the re-used block).Â
When using an ART or Nucleo blocker, Rx-Universe can be configured to select the correct block piece and print it on the work ticket.Â
To set up the block pieces and the selection rules, please see Setting Up and Selecting ART and Nucleo Blocks.
The Nucleo blocker also sends back information on the block/blank geometry, which Rx-Universe will save and use for subsequent communication with other equipment. One of the pieces of information sent back by the Nucleo is the measured front curve of the blank that has been blocked. If the measured front curve differs from the stored front curve in Rx-Universe, value used for the calculation, Rx-Universe will automatically re-calculate the job; if the measured front curve differs from the stored front curve by a large amount, this may indicate the wrong base curve was pulled, and the job can be placed on hold for manual investigation. The tolerances for triggering re-calculation, and for triggering when the job should be placed on hold, can be set up in Rx-Universe, please see instructions here.