Version 7.49.01

released 12 July 2022

Licensing and Downloads

For labs that are licensed to run without a dongle, when Rx-Universe connected to the license server to validate the session, not all connections were being terminated after use. This could result in an excess of open connections and cause either slowdowns or access issues for some Rx-Universe customers. Connections are now all properly terminated after use.

The speed of downloading lens data, Eyefinity codes, VCA label table entries, and other information, has been greatly increased. Downloading Eyefinity lens codes, for example, which previously could take 2-3 hours, can be expected to complete in less than 10 minutes.

Orders

Fix an issue that was causing blank selection to list clear blanks for a pre-treatment that could not be applied to a lens. This was only occurring when the pricing module was turned off.

Device interfaces

The VCA device interface has been modified for the SatisLoh ART-A blocker when a one-eye job is blocked.

The VCA device interface, did not take into account that the ART auto-blocker can send both eyes in the same upload.

Digital processor

When processing the LMS response file, if either CIRC or ELLH were contained in the LMS file, and the lab is setup to use ART blocking, the BLKRD and BLKDM did not get recalculated based on the new CIRC or ELLH values.