Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Firewall Requirements

Rx-Universe uses active ftp to send orders to Opticom.  As of October 2018, firewall requirements have changed in order to transmit to Opticom's ftp server.

In the lab's firewall, ensure that all TCP ports are open for incoming communication from IP 65.52.204.137.

In Windows Firewall:

  1. Create a new inbound rule (Inbound Rules, New Rule)
  2. Select "port", click "Next"
  3. Select "TCP" and "All local ports", click "Next"
  4. Choose "Allow the connection" and click "Next"


  5. Enter a description and click "Next"
  6. Double-click on the new rule that was created:
  7. Click on the "Scope" tab, and change the Remote IP Address to be 65.52.204.137, as shown below.  This restricts opening all incoming TCP ports to just connections from Opticom.
  • No labels