Search Optifacts User Documentation
Live Search | ||||
---|---|---|---|---|
|
Table of Contents (on this page)
Table of Contents | ||||||
---|---|---|---|---|---|---|
|
Introduction
This document provides instructions for setting up ...
Procedure
Configuring Tray Track Scanner / Bar Code Readerbarcode Reader ID and Station ID numbers
Procedure
This section assumes your scanner/reader is already programmed to work with Optifacts Tray Track. Optifacts Support will assist with configuring your scanner if needed.
This Quick Note configures the stations you can scan with a given scanner/reader.
This appliesCustom Configuration
Applies to scanners attached to the Job Track interface only; it does not apply to scanners connected to a terminal.
From the
Main Menu, select #7 - Tray TrackOptifacts main menu:
Select Option 3 – Editor Utilities and press Enter.
Select Option 6 – Configuration Editor and press Enter.
Select Option 6 – Edit Custom Configuration and press Enter.
The Custom Configuration Editor displays.
- Press “Q” to Query.
- Ensure that the table below exists.
If the table does not exist:
- Press “A” to add a new record.
- Enter all the information as shown in the diagram below.
- Press Escape to save the data.
- Press “E” to exit.
Configuring Tray Track Scanner / Bar Code Reader
From the Optifacts main menu:
Select Option 7 - Tray Track and press Enter.
Select Option 12 - Tray Track Configuration and press Enter.
Select Option 3 - Reader ID & Station ID/Number Setup and press Enter.
The Station Number Setup screen is displayed.
Press 'a', 'b', 'c'- Press “a,” “b,” “c,” or whatever letter has been designated is for the reader you are about to update.
The following screen displays.
- Enter the Sub-Master Station Number you want to add. As soon as this you enter the number is entered, the description for the number will be is displayed.
- Enter as many Sub-Master Station Numbers as you need. Each Sub-Master Station you enter can be scanned at the reader you are configuring.Any Any station ID that is not assigned a Sub-Master Station will have no effect when attempting to scan that station ID at the scanner/reader.
- Enter through all of the remaining upper case Station ID fields.
There will be a second screen of lower case Station ID
which you will also have to enter through.that displays.
- Press Enter through all the fields.
After entering past the last field, respond to the question that appears.
Are The Entries Correct (Y) Yes / (R) Review / (S) Start Over
Only an answer of
'Y'‘Y’ will save the entries.
- Answering 'R' Press “Y” if correct and to save the data.
- Answering “R” lets you review your changes.
- Answering 'S' “S” will erase your changes and start over from the first entry.
Your screen is now completed
The form is complete, and the new Station
ID's will beIDs are available for use.
- You may now configure another reader , or press 'Esc' Escape to exit to the Optifacts menu.
This article comes from the Optifacts SupportWeb.Example
To view and download these instructions as a PDF file, click on the following document image.
View file name Reader ID & Station ID Setup.pdf height 250