Search Optifacts User Documentation
Table of Contents (on this page)
Introduction
This document will explain how to navigate and input data using your keyboard. Optifacts has several different types of screens. Each has standards for navigating and inputting data.
Features
- Speed - The order entry system is quick to use because it skips those windows and fields that do not apply to the calculations entered for the job. The system displays only those options that are requested to view. If the correct code and seg for the style are known, showing the style list is not required. The calculation list does not need to open if the options are not required.
- Rx Form – Information is organized in the system to reflect the order of information listed on the typical Rx form.
- Windows - All information is entered and displayed in windows, rather than in screens. Some windows within view for every job; others are displayed only under specific circumstances. As a window is complete, the next appropriate window will be displayed slightly below the previous window. You can effortlessly move to the prior window by pressing the Escape (ESC) key.
- Fields - Some fields are displayed for every lens selected; others appear only if a specific lens is selected. Some windows show all data fields, but access only those applicable to the job. That is, the system will access a data field if it applies to the calculations entered.
Definitions
- Order Entry - The Order Entry function allows you to enter all measurements, curves, and blocking needed to create the prescribed lens. If pricing is active, then invoicing information is recorded.
- Optifacts Blocking – Design of the Optifacts software allows on geometric lens center blocking or MRP (Manufacturer Reference Point) blocking for lens surfacing. The system will compute the prism required to place optical centers, the prism direction, and the segment positioning required at Order Entry. When on center blocking is used, a single vision must be blocked as close as possible to the geometric center of the lens. However, blocking Multifocals should not be on the geometric center as determined by available blank center locating methods. Rather, referencing up and over from the segment equal to the layout seg down and seg in amounts. MRP blocking is also available and is automatic for aspheric and progressive lenses. On the work ticket, the system will list the blocking method at the top and the measurements under Surfacing Markup.
- Right-Eye Assumption - The system always assumes the right eye calculations entered first. In any window with calculations, for both eyes, the system will first ask for the right eye, then left eye. And, if working with only one lens, you can signal the system to prompt for that lens only, left or right.
- Right, and Left lenses are labeled as R and L in the Rx window. In all other windows, two lines indicate the first line as right and the bottom line as left. The right lens is always on the first line, as shown in the Rx screen.
Procedure
Access the order entry screens from the Optifacts menu option 4.
Entering Values in Order Entry
Values for various materials are input in the fields illustrated below. Inputting these values is similar to inputting dollar amounts. You must type the decimal point in the numeric entry. For example, if you want to input an entry of 3.5 for the Sphere, you would type 3, the period, and the 5. When you press Enter, the number appropriately aligns within the field. Some fields default to an entry when you Enter through it.
*** Caution: If you do not type a decimal, all numbers typed will fall to the left of the decimal after pressing the Enter key. ***
Help Keys and Shortcuts
Use the table below for instructions on navigating through the order entry screens and inputting data.
Key | How it's used |
---|---|
Press F1 to display the Help window for the field the cursor is. Some help texts are more lengthy than will fit on one page; press the space bar to continue to the next page. (See prompt 'more...' at the bottom of the screen.) Press ESC to exit the Help window and return to the field. | |
Press F2 to display the Calculations Options window. The status message at the bottom of the screen will tell you when you can access the Calculation Options window. | |
Press F3 to return to the first field in a window. | |
Press F4 to move to the last field in a window. | |
Press F5 to utilize the Phone Rx screen. | |
Press Ctrl Y to toggle the CBT (Commercial Brand Tool) and/or CPS (Commercial Product Selector) menu. | |
The status message at the bottom of the screen will tell you the result of pressing ESC in each window. In the Tray & Acct. window, press ESC to exit Order Entry. Pressing ESC anywhere in this window will exit Order Entry. Use the arrow keys or F3 to back up. In the Frame Information window at the first field (Frame name or shape): press ESC to return to the Blank window. After the first field, press ESC to return to the first field. In the Near Prism window, press ESC to restart the window. In all other windows, press ESC to return to the previous window or screen; ESC backs up one window at a time. | |
Press the Insert key to access the Recall Options screen. | |
Press Enter to advance to the next field or to complete the order when at the pricing options screen. Caution: The Enter key saves data in a field. If you move between fields using the arrow keys, the data is not saved. If you try to store information using a Tab key, the cursor will not move and you will receive an error sound (if your system is configured for sound). | |
The Space bar can be used to:
| |
Use the question mark (?) key to see the available options for a field. Example: To see a list of customers in the Account field, or to see a list of options in any other order entry field. | |
Press the Page Up key to move to the previous section. | |
Press the Page Down key to move to the next section. | |
Use the END key to navigate to the end of the Rx and reprint the work ticket | |
Press the Left Arrow key to move backward by one field or one page in the pricing options screens. | |
Press the Right Arrow key to move forward by one field or one page in the pricing options screens.
Caution: When you navigate using the arrow keys, your data will not save. You must use the Enter key to 'save' data. If you try to store information using a Tab key, the cursor will not move and you will receive an error sound (if system configured for audio). | |
Press S in the Patient Name field to access the Safety/Copay Account Code field | |
Press V in the Patient Name field to add the VSP account code. | |
Press C in the Patient Name field to access the CBT Selection menu. | |
Press S in the Style w/Seg Sz field to access the Special Entry screen. | |
Press L in the Frame Name field to access the frame library. | |
Press I in the Frame Name filed to access frame inventory. |
To view and, or download these instructions as a PDF file, click on the following document image.