Introduction

This document provides instructions for integrating FCS.

Procedure

Approval

RTS coordinates with Lab Management for the installation of FCS.

Certification

RTS to ensure equipement is cerfied to process FCS. This certification process includes installing the appropriate software updates for the lab equipment.

Installation Date

Once approved and certified, RTS to coordinate with Lab Management on a go-live date.

Communication

RTS to communicate the FCS go-live dates. Communication is usually four weeks before FCS go-live.

Info

Traditional labs require Demons to be bounced. RSS to coordinate with operations to stop and restart the Demons once all the configurations are complete.

Verification

RSS must verify that Optifacts has the following working directories;

/u/optifacts/from_rxcp

/u/optifacts/to_rxcp

/u/optifacts/from_scg

/u/optifacts/to_scg

Ensure that Optifacts has the following directories for machinery;

/u/optifacts/lohes3

/u/optifacts/lohes4

/u/optifacts/opt7e

/u/optifacts/essblu

/u/optifacts/opt7esh (shallow blade)

Info

All tracers at the lab should be set to non-FCS three weeks before deployment. (OMA tracers only) Labs should always have non-FCS tracers for non-FCS work. Small labs should have an A/B Switch to change the tracers from FCS to non-FCS (Prescriptor Jobs).

Custom Configurations

RSS to get the IP for the following and then configure the following custom configurations.

        You should query these entries and only add the missing configurations.

RXCP Server IP

Calling Program:   [LAYOUT    ]

Field Name:        [SCG SOCKET IP/PORT  ]

Enabled:           [Y]

Character Setting: [172.21.245.109                                                         ]

Float Setting:     [1.0           ]

Integer Setting:   [1233       ]

Comment:           [Put SCG IP address in Char, port # in Integer     ]

RXCP Socket Timeout Setting

Calling Program:   [LAYOUT    ]

Field Name:        [SCG CHECK LOOP COUNT]

Enabled:           [Y]

Character Setting: [                                                                      ]

Float Setting:     [              ]

Integer Setting:   [120        ]

Comment:           [Define recap socket timeout. Integer in seconds.   ]

Create RXCP Output

Calling Program:   [LAYOUT    ]

Field Name:        [CREATE RXCP OUTPUT  ]

Enabled:           [Y]

Character Setting: [sockets, from_rxml                                                    ]

Float Setting:     [3600.0        ]

Integer Setting:   [15         ]

Comment:           [Creates an RxML Output File for RxCP.             ]

Finishing Calc’s Through RXCP

Calling Program:   [LAYOUT    ]

Field Name:        [FCS CALCS THRU RXCP ]

Enabled:           [Y]

Character Setting: [                                                                      ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [Enable to get finishing calcs from FCS            ]

RXCP Socket Server ( this will be a running program started thru menu 10-2

Calling Program:   [STARTUP   ]

Field Name:        [INTERFACE 30        ]

Enabled:           [Y]

Character Setting: [./progs/rxcp_server 1233 &                                            ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [RxCP Socket server                                ]

FCS Direct Connection Through RXCP

Calling Program:   [LAYOUT    ]

Field Name:        [FCS CALCS WTHOUT SCG]

Enabled:           [Y]

Character Setting: [sockets,from_rxml                                                     ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [Connect with FCS directly through RxCP         ]     

FCS Start date. (Normally, the date you enable this config.)

Calling Program:   [LAYOUT    ]

Field Name:        [FCS START DATE      ]

Enabled:           [Y]

Character Setting: [04/15/2011                                                            ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [Enter start date when FCS was turned on.          ]

RXML Schema (2006 unless otherwise told)

Calling Program:   [LAYOUT    ]

Field Name:        [RXML SCHEMA VERSION ]

Enabled:           [Y]

Character Setting: [2006                                                                  ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [Character Setting:  Version (2005, 2006, etc.)    ]

Debug Option

Calling Program:   [LAYOUT    ]

Field Name:        [RXCP DEBUG          ]

Enabled:           [Y]

Character Setting: [                                                                      ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [Enable this option to print debug into demon log   ]

Skip Sending Patient Name to RXCP

Calling Program:   [LAYOUT    ]

Field Name:        [SKP SAVE PAT 2 RXML ]

Enabled:           [N]

Character Setting: [                                                                      ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [If enabled, dont send patient name to RxCP        ]

Default Frame Curve Value ( 4.5 is the default but may change ask RTS)

Calling Program:   [LAYOUT    ]

Field Name:        [PRNT DEFLT FCS FRCV ]

Enabled:           [Y]

Character Setting: [                                                                      ]

Float Setting:     [4.5           ]

Integer Setting:   [           ]

Comment:           [Default FCS FCRV value printed on work ticket     ]

Remote Edging  Configuration

Calling Program:   [LAYOUT    ]

Field Name:        [SEND OMA IN OPTI2.8 ]

Enabled:           [Y]

Character Setting: [                                                                      ]

Float Setting:     [              ]

Integer Setting:   [           ]

Comment:           [send oma trace file in the opti2.8 file                     ]

A configuration is added to Optifacts to capture the bevel placement. This configuration is optional by the lab, so the default should be Enabled=N unless specified by RTS or RxTech Team.

Calling Program:   [LAYOUT    ]

Field Name:        [BEVP SCRN IN LAYOUT ]

Enabled:           [N]

Character Setting: [                                                                      ]

Float Setting:     [1.0           ]

Integer Setting:   [           ]

Comment:           [Bevel entry menu in layout, flt is BEVM val for FF]

The configuration above adds a screen after “frame info” through Rx Entry to capture.

  • Edging Parameters

0) Normal Edging

1) 1/3 - 2/3 Back

2) 50% Back

3) Flush Front

4) Specify Position  (OMA)

Choice = [0 ] 

Info

Traditional labs require Demons to be bounced once the above configurations are added. (see step 4)

FCS Machinery Setup

Most of the machinery setup gets done by the RTS team. RSS is responsible for the Optifacts equipment matrix table (Optifacts Menu 3-6-17).       

Info

Restart the tracers in (Optifacts Menu 10-2) after updating the tracers or removing the non-FCS tracers from the character settings in (Optifacts Menu 3-6-6).

Edger Setup

For edgers, we must define the FCS file directory and “two eye send” (example changes below in red, directory name get determined by edger type, i.e., Optronic 7E (opt7e)

Loh ES4 (lohes4)

Loh ES3 (lohes3)

Port Name:  ttya25

Device Name         C4-EDGER #13 7E

Bevel Position      N       Value      7        Bevel C/M         0.00

Back Pin Bevel      N       Value     0.00

Frnt Pin Bevel      N       Value     0.00

Polish Mode         N       Value     0

Groove Depth        N       Value     0.00      Groove Width   0.00

Groove Edge         N║

Drill Edge          N

Gen Safety Bevel    N       Value     0.00

Two Eye Send        Y

Digital File        N       Value     1

FCS Directory Name  opt7e

Number Trc R Point   400    Number Trc Z Point   400

Lens Mat ID         T

Optronic 6E

Port Name:  ttya18

Device Name         OPTRONICS 6E #1

Bevel Position      N       Value      7        Bevel C/M         0.00

Back Pin Bevel      N       Value     0.00

Frnt Pin Bevel      N       Value     0.00

Polish Mode         N       Value     0

Groove Depth        N       Value     0.00      Groove Width   0.00

Groove Edge         N║

Drill Edge          N

Gen Safety Bevel    N       Value     0.00

Two Eye Send        Y

Digital File        N       Value     1

FCS Directory Name  opt7e

Number Trc R Point   400    Number Trc Z Point   400

Lens Mat ID         T

Tracer Setup LT-1000

For tracers, what is important are the trace points and Z points. ( Settings in red below )

Set these as indicated below. If not, the output Optifacts uses is 512 points

Port Name:  ttya19

Device Name         tracer lt1000

Bevel Position      N       Value      7        Bevel C/M         0.00

Back Pin Bevel      N       Value     0.00

Frnt Pin Bevel      N       Value     0.00

Polish Mode         N       Value     0

Groove Depth        N       Value     0.00      Groove Width   0.00

Groove Edge         N

Drill Edge          N

Gen Safety Bevel    N       Value     0.00

Two Eye Send        N

Digital File        N       Value     1

FCS Directory Name

Number Trc R Point   800    Number Trc Z Point   400

Lens Mat ID         N

Additional Information

The following lens styles are non-FCS and must get traced on a non-FCS tracer.

        Always handle Glass as non-FCS. (Example Topeka)

Traditional Lens Styles:

  • Glass -ALL

  • Executives – ALL

  • Lenticulars -ALL

Digital Shamir Products:

  • Autograph II Attitude

  • Autograph II Attitude Short

  • Autograph II Attitude SV

  • Autograph II Fixed

  • Autograph II Office

  • Autograph II SV

  • Autograph II Attitude Variable

  • Autograph III Fixed

  • Autograph III Variable

  • Element

  • Element Short

  • Firstpal

  • Golf

  • Golf SV

  • Intouch

  • Intouch Short

  • Relax

  • Spectrum

  • Spectrum SV

Digital Kodak Products:

  • Directek

  • Directek Short

  • Kodak Concise Digital

  • Kodak Precise Digital

  • Kodak Precise DB

  • Kodak Precise Short Digital

  • Kodak Precise Short PB

  • Kodak Unique

  • Kodak Unique DS

  • Kodak Unique Monitorview

  • Signetek Processed SV

Digital Definity 3 Products:

  • Definity 3

  • Definity 3 Plus

Varilux S Products:

  • VX S 4D (without head eye)

  • VX S Design



  1. Post FCS Calculation Review Notes


  1. Troubleshooting and Notes

RTS is responsible for changing the edgers settings for OMA initial level to Full. Once these settings are changed, you have to bounce the edger in (Optifacts Menu 10-2) by killing and restarting the port. The job will not pull up on the edger if this step is not complete.

If RTS enables a 6Es edger that uses the same blade as a 7Es, the job file will be in the opt7e directory.

  1. Additional FCS Approved Equipment List

  • me1000

  • me1200

  • mei641

  • meibis


Post FCS Calculation Review (FCS Enabled Laboratory)

ð   = most important

Printed on Work Ticket:

Resolution:

ð                         B / B <no code> =

Review - if the difference is > 0.75 on PLUS or > 1.25 on MINUS, it should change to % mode (may get 6900 warning but is ok). Otherwise, run as is

ð                               B / B 5900 =

Review - Outside of flex rules, and is severe. Should be changed if possible to % mode or change lens curve to a better fit

ð                               B / B 5932 =

Review - Frame curve difference between R/L > 1.00 diopter and influencing bevel position

ð                         A / A <no code> =

Review - Complete failure to calculate, determine what failed, or run non-FCS

F / F 5900 (Polaroid) =

Review - May also have CHK BASE on ticket, change Lens Curve if needed, or allow the frame to adjust

F / F 5902 (Groove) =

Review - Groove too close to the edge (< 0.5mm from either edge). Change to % mode (others can be ignored)

<any> / <any> 5930 =

Review - A size (HBOX) difference between R/L > 1.0 mm, can usually be ignored

<any> / <any> 5931 =

Review - B size (VBOX)  difference between R/L > 1.0 mm, and should be corrected or trace 1 eye only

<any> / <any> 3903 =

Review - Check for double convex tooling, and correct it if possible. Otherwise, run non-FCS



A / A =

Return/Redo - needs to be “Re-Launched”  if FCS, using additional steps or retrace frame if possible

1908 =

E-Tess error – trace on LT1000 (if no other tracer available, run non-FCS)

A / A 1907 =

Trace Error - Will need both sides of frame traced to calculate or FRAME TYPE wrong at Layout



ð               F / F 6900 (Polaroid) =

Ignore - Unless CHK BASE  is on the ticket or normal Polaroid review (for wrap types)

P / P 6900 =

Ignore – usually in % mode because of “nose pad collision” or “thin edge.”

B / B 6900 =

Ignore - Outside of flex rules, but not severe, usually OK to process

F / F 5932 =

Ignore - Following lens curve so difference in frame (FCRV) curve R/L is not an influence

5901 or 5910 or 5920 =

Ignore - Lens thickness < FCS minimum default, if surfaced too thin, results will be too

R =

Ignore - Rimless job and can be run anywhere (If not Rimless, it might mean the lite-up #19 was used)

S / P or P / S (Groove) <no code> =

Ignore - Regular % mode, where 1 eye is 50% other eye < 50%

S / S <no code> =

Ignore - Same a P / P only in 50% mode



ALL OTHER CODES =

Review





To view and download these instructions as a PDF file, click on the following document image.