Introduction
This document covers removing a frame trace from both the trace library and removing the link from a Frame Inventory record.
Procedure
From the Optifacts main menu:
Type Select Option 3 - Editor Utilities and press enterEnter.
Type Select Option 2 - Frame Database Editor and press enterEnter.
Type Select Option 8 - Retrieve Trace from Library and press enterEnter.
The Retrieve Trace Data from Trace Library screen displays.
- Enter enough information to locate the frame in question. You can use an asterisk (*) as a wildcard character to help locate the frame.
- Answer Y “Y” when the correct frame is gets displayed on the screen.
More information about the frame is displayed.
- Answer Y “Y” if the information displayed is correct for the frame.
If you answered Y “Y” above, you are now get asked if you want to remove this Frame.
- Do you want to remove this frame (Y/N or R to Remove from remotes)? [Y]
- Answer Y. “” (This will NOT remove the Frame Inventory record, it will just remove the trace from being associated with the Inventory record)
If you answered Y“Y,” the screen will return returns to the first prompt for the frame name. The tracing record you had been working with is now gets removed.
If you need to remove another tracing, repeat the process.
- Press escape Escape to exit the screen..