Introduction

This document provides instructions for enabling the relaunch function and setting up a system to allow operators to launch a new job by looking up an original job through Quick Lookup or the Quick Lookup View of Archived Jobs.  

Info

Relaunch must be configured before jobs begin storing for later Relaunch. Jobs previous to the Relaunch setup date are not available for Relaunch. Tray Track must also be enabled.

Procedure

Custom Configuration

Enable the following custom configuration.

From the Optifacts main menu:

Select Option 3 – Editor Utilities and press Enter.

Select Option 6 – Configuration Editor and press Enter.

Select Option 6 – Edit Custom Configuration and press Enter.

The Custom Configuration Editor displays.

  • Press ‘Q’ to Query if the table you are looking for exists.

If the table does not exist:

  • Press ‘A’ to add a new record.
  • Enter all the information, as shown in the diagram below.
  • Press Escape to save the data.
  • Press ‘E’ to exit.
Info

The Relaunch feature can only be utilized on jobs run through Order Entry starting from the date that the following configuration is enabled. You can not relaunch jobs previous to the setup date. Tray Track also needs to be set up.

If the following custom configuration is enabled, when you relaunch a job, you get asked to enter a tray number, and we go through auto lite-ups when the job is processing.

Route Condition

Set up the following Job Routing Condition required to relaunch a job.

From the Optifacts main menu:

Select Option 3 - Editor Utilities and press Enter.

Select Option 11- Job Routing Menu and press Enter.

Select Option 9 – Route Conditions Control Editor and press Enter.

The Job Routing Condition Control Manager is displayed.

  • Press ‘Q’ to Query if the table you are looking for exists.

If the table does not exist:

  • Press ‘A’ to add a new record.
  • Enter all the information, as shown in the diagram below.
  • Press Escape to save the data.
  • Press ‘E’ to exit.
Note

Do not attach this condition to a Destination Site.

Lite-up Controls

Set up lite-up controls to control which lite-ups eligible for Relaunch.

Info

Example: ‘SUPPLY FRAME’ may not be appropriate on relaunched jobs, so you can store the OPTI2.8 file without ‘SUPPLY FRAME’ lit even if lit on the original job.

From the RX Transfer Menu:

Select Option 10 – Route Conditions Lite-Up Editor and press Enter.

  • Press ‘Q’ to Query if the table you are looking for exists.

If the table does not exist:

  • Press ‘A’ to add a new record.
  • Enter all the information, as shown in the diagram below.
  • Press Escape to save the data.
  • Press E to exit.

Retail Transfer Field Location

Next, you need to set up the Lens Manufacturer Code in the Field Location Editor to interpret the manufacturer codes that get stored with archived jobs. 

From the Optifacts Main Menu:

Select Option 11- Retail Transfer and press Enter.

Select Option 4 - Editor: Field Location and press Enter.

  • Press ‘Q’ to Query if the table you are looking for exists.

If the table does not exist:

  • Press ‘A’ to add a new record.
  • Enter all the information, as shown in the diagram below.
  • Press Escape to save the data.
  • Press ‘E’ to exit.
Info

Be sure to fill in the Field Notes, as well as the Starting and Ending Markers that appear in the lower portion of the screen.

Restart Calculations and Translay.

You must restart the Calculations Module and Translay programs.

From the Optifacts Main Menu:

Select Option 10 - Management Functions and press Enter.

Select Option 2 - Check Restart Optifacts Programs and press Enter.

Info

Only jobs that entered through Order Entry from this point on are available for Relaunch. 



To view and download these instructions as a PDF file, click on the following document image.