Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Search Optifacts User Documentation

Table of Contents (on this page)


Introduction

This document outlines FCS Warning/Error Codes.

Warning Codes by Frame Type:


Code:

5930


Frame Type:

Full Rim

FCS Message:

Check HBOX consistency between sides

Explanation:

Difference between Right & Left “A” size exceeds tolerance level

Severity Level:

Medium

Results:

Calculates, with warning on ticket

Sources:

FCS settings: tolerance = 1.0 mm difference

Corrective Actions:

1) Validate as OK to use (as is)

2) Stabilize the two sides within tolerance level and trace again

3) Trace the “better” of the two sides and be aware that a size error might exist


Code:

5931

 

Frame Type:

Full Rim

FCS Message:

Check VBOX consistency between sides

Explanation:

Difference between Right & Left “B” size exceeds tolerance level

Severity Level:

High: If not corrected, may result in dissimilar seg heights or poor cosmetic acceptance

Results:

Calculates, with warning on ticket

Sources:

FCS settings: tolerance = 1.0 mm difference

Corrective Actions:

1) Validate as OK to use (as is)

2) Stabilize the two sides within tolerance level and trace again

3) Trace the “better” of the two sides and be aware that a size error might exist


Code:

5932

 

Frame Type:

Full Rim

FCS Message:

Check FCRV consistency between sides

Explanation:

Difference between Right & Left frame curve (FCRV) exceeds tolerance level

Severity Level:

Very High: May result in poor beveling between R/L side, if not within tolerance

Results:

Calculates, with warning on ticket

Sources:

FCS settings: tolerance = 1.00 diopter difference

Corrective Actions:

1) Validate as OK to use (as is)

2) Stabilize the two sides within tolerance level and trace again

3) Trace the side closest to the lens curve, and be aware of sizing problems (set large as insurance)


Code:

6900

 

Frame Type:

Full Rim

FCS Message:

Small difference between bevel and frame curve

Explanation:

Curve difference is slightly higher than frame flexibility but less than 0.50 diopters

Severity Level:

Low: Will likely not result in a poor bevel

Results:

Calculates, with warning on ticket

Sources:

FCS settings: frame flexibility = +/- 2.00 diopters, CurveGapMaximum = 3.00 diopters

Corrective Actions:

1) Review differences between applied bevel position & lens curve – if acceptable, proceed

2) Pick lenses closer to frame curve

3) Reduce/Increase frame curve closer to lens curve and trace again

4) Change beveling to another type (Layout operation)


Code:

5900

 

Frame Type:

Full Rim

FCS Message:

Excessive difference between bevel and frame curve

Explanation:

Curve difference is much higher than flexibility and exceeds <CurveGapMaximum>

Severity Level:

Very High: Will likely result in a non-aesthetic bevel position if not corrected or reviewed

Results:

Calculates, with warning on ticket

Sources:

FCS settings: frame flexibility = +/- 2.00 diopters frame, CurveGapMaximum = 3.00 diopters

Corrective Actions:

1) Review differences between applied bevel position & lens curve – if acceptable, proceed

2) Pick lenses closer to frame curve

3) Reduce/Increase frame curve closer to lens curve and trace again

4) Change beveling to another type (Layout operation)


Code:

5901

 

Frame Type:

Full Rim

FCS Message:

Check lens thickness

Explanation:

Lens is thinner than tolerance

Severity Level:

Low

Results:

Calculates, with warning on ticket

Sources:

FCS settings: minimum thickness = 1.4 mm (we grind some materials to less than a 1.4 min edge)

Corrective Actions:

1) Validate lens thickness, and if acceptable, ignore warning and proceed

2) Make lenses the correct thickness


Code:

5902

 

Frame Type:

Full Rim

FCS Message:

Selected bevel position is not a good fit

Explanation:

Bevel curve specified (manual input) and FCS does not agree with our choice

Severity Level:

Medium

Results:

Calculates, with warning on ticket

Sources:

Operator specified bevel curve inappropriate for lens curve

Corrective Actions:

1) Remove requested bevel position/curve, and process through FCS again or validate as ok

2) Common on Polaroid’s since they always bevel to lens curve regardless of frame curve

3) Run on non-FCS edger using another bevel (e.g. “automatic”) setting.


Code:

5903

 

Frame Type:

Full Rim

FCS Message:

Severe differences between frame and lens curves

Explanation:

Difference between frame curve (flexed) & lens curve severe

Severity Level:

Very High: Will result in a non-aesthetic bevel position if not corrected or reviewed

Results:

Calculates, with warning on ticket

Sources:

FCS settings: AAT function not active

Corrective Actions:

1) Change lens curve, bend frame closer, or change frame flex amount

2) Specify a different bevel position at Layout, and re-process

3) Run on non-FCS edger using another bevel setting (manual by operator)




Code:

5910

 

Frame Type:

Groove & Metal Wire

FCS Message:

Check lens thickness

Explanation:

Lens too thin to groove and maintain the minimum thickness

Severity Level:

High

Results:

Calculates, with warning on ticket

Sources:

FCS settings: tolerance = 0.5 mm to either side of groove (default width = 0.7 mm**)

Corrective Actions:

1) Validate lens thickness, and if acceptable, ignore warning and proceed

2) Make lenses the correct thickness

** 0.7 mm wide is the default for ES-types. It is configured to lesser widths for the 6E/7E edgers

Code:

5911

 

Frame Type:

Groove & Metal Wire

FCS Message:

Selected groove position is not a good fit

Explanation:

Specified grooving curve will not fit in the lens

Severity Level:

High

Results:

Calculates, with warning on ticket

Sources:

Operator specified groove curve inappropriate for lens curve

Corrective Actions:

1) Remove requested groove curve, and process through FCS again

2) Run on non-FCS edger using another groove (e.g. “standard”) setting


Code:

5963

 

Frame Type:

Groove & Metal Wire

FCS Message:

No edger capable of specified groove

Explanation:

Specified Width and/or Depth exceeds limits of equipment

Severity Level:

High

Results:

Calculates, with warning on ticket

Sources:

FCS settings file limit

Corrective Actions:

1) Validate width/depth parameters and if acceptable, proceed

2) Change width/depth manually on edger and proceed

3) Contact technical support for changes or corrections


Code:

5920

 

Frame Type:

Rimless

FCS Message:

Check lens thickness

Explanation:

Lens thickness less than minimum level set

Severity Level:

Medium

Results:

Calculates, with warning on ticket

Sources:

FCS settings: minimum thickness = 1.8 mm

Corrective Actions:

1) Validate lens thickness, and if acceptable, ignore warning and proceed

2) Make lenses the correct thickness


Code:

5973

 

Frame Type:

Rimless

FCS Message:

No defined edger capable of drilling

Explanation:

Edger was expected to physically drill the lens and is not defined to perform that action

Severity Level:

Low

Results:

Calculates, with warning on ticket

Sources:

FCS setting file limits

Corrective Actions:

1) Review FCS settings file for possible corrections (if an edger is capable)

2) Rimless is not actually calculated (adjusted) for drill work. Can typically be run on any edger in the building (FCS or not) and drilled external to edger or by use of internal database on edger


No Calculation Codes by Frame Type:

Code:

1906

 

Frame Type:

All

FCS Message:

Traced wrong side of single eye job (using a lens/pattern for shape)

Explanation:

Single eye job where the tracing is for the wrong side

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Tracing operator traced wrong side on a single eye job

Corrective Actions:

1) Trace same side as the RX lens to produce

2) If not possible to trace the RX side, run on non-FCS edger


Code:

1916

 

Frame Type:

All

FCS Message:

Requested edge data incomplete

Explanation:

Requested bevel position (BEVP) does not contain the other data required (BEVM)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

Operator specified bevel positioning incomplete

Corrective Actions:

1) Add missing component to specified request and submit to FCS

2) Remove request and let system (FCS) decide bevel positioning


Code:

1907

 

Frame Type:

Full Rim

FCS Message:

Both sides must be traced on full rim frames

Explanation:

Full rim frame must have both sides traced on a two eye job

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Tracing operator did not trace both sides of a full rim frame

Corrective Actions:

1) Trace both sides

2) If not possible to trace both sides, run job on non-FCS edger


Code:

5950

 

Frame Type:

Full Rim

FCS Message:

Lens curve beyond limits of edger

Explanation:

Lens curve higher than defined limits of equipment

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

FCS setting file limits

Corrective Actions:

1) Review FCS settings file for possible corrections (if edger is capable)

2) Outsource to facility with appropriate equipment

3) Run on non-FCS or specialized equipment that can provide edging


Code:

5951

 

Frame Type:

Full Rim

FCS Message:

Potential block crash on edger

Explanation:

B size of shape is smaller than assumed minimum edger capability – block crash warning

Severity Level:

Medium

Results:

No calculation provided, warning on ticket

Sources:

Internal FCS setting: Minimum “B” value is defined by edger model

Corrective Actions:

1) Verify that block size smaller than minimum lens size and run on non-FCS edger

2) Likely that probe and/or block will leave a “bump” on edge requiring hand work


Code:

5952

 

Frame Type:

Full Rim

FCS Message:

No edger defined for this lens material

Explanation:

Lens material is not defined in edger list

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

FCS settings file

Corrective Actions:

1) Review FCS settings file for possible corrections (if an edger is capable)

2) Outsource to facility with appropriate equipment

3) Run on non-FCS equipment that can provide edging


Code:

1917

 

Frame Type:

Groove & Metal Wire

FCS Message:

File missing groove depth or width

Explanation:

Incoming file does not contain groove information for FCS calculation

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Frame type is groove but no depth / width in incoming file to FCS

Corrective Actions:

1) Specify values and submit

2) Run on non-FCS edger and input/use edger values

3) LMS system error (missing default values) – call technical support


Code:

5960

 

Frame Type:

Groove & Metal Wire

FCS Message:

Lens curve beyond limits of edger

Explanation:

Lens curve higher than defined limits of equipment

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

FCS setting file limits

Corrective Actions:

1) Review FCS settings file for possible corrections (if an edger is capable)

2) Outsource to facility with appropriate equipment

3) Run on non-FCS equipment that can provide edging


Code:

5961

 

Frame Type:

Groove & Metal Wire

FCS Message:

Potential block crash on edger

Explanation:

B size of shape is smaller than assumed minimum edger capability – block crash warning

Severity Level:

Medium

Results:

No calculation provided, warning on ticket

Sources:

Internal FCS setting: Minimum “B” value is defined by edger model

Corrective Actions:

1) Verify that block size smaller than minimum lens size and run on non-FCS edger

2) Likely that probe and/or block will leave a “bump” on edge requiring hand work


Code:

5962

 

Frame Type:

Groove & Metal Wire

FCS Message:

No edger defined for this lens material

Explanation:

Lens material is not defined in edger list

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

FCS settings file limits

Corrective Actions:

1) Review FCS settings file for possible corrections (if an edger is capable)

2) Outsource to facility with appropriate equipment

3) Run on non-FCS equipment that can provide edging


Code:

5970

 

Frame Type:

Rimless

FCS Message:

Lens curve beyond limits of edger

Explanation:

Lens curve higher than defined limits of equipment

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

FCS setting file limits

Corrective Actions:

1) Review FCS settings file for possible corrections (if an edger is capable)

2) Outsource to facility with appropriate equipment

3) Run on non-FCS equipment that can provide edging

Code:

5971

 

Frame Type:

Rimless

FCS Message:

Potential block crash on edger

Explanation:

B size of shape is smaller than assumed minimum edger capability – block crash warning

Severity Level:

Medium

Results:

No calculation provided, warning on ticket

Sources:

Internal FCS setting: Minimum “B” value is defined by edger model

Corrective Actions:

1) Verify that block size smaller than minimum lens size and run on non-FCS edger

2) Likely that probe and/or block will leave a “bump” on edge requiring hand work


Code:

5972

 

Frame Type:

Rimless

FCS Message:

No edger defined for this lens material

Explanation:

Lens material is not defined in edger list

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

FCS setting file limits

Corrective Actions:

1) Review FCS settings file for possible corrections (if an edger is capable)

2) Outsource to facility with appropriate equipment

3) Run on non-FCS equipment that can provide edging


Code:

1911

 

Frame Type:

Rimless

FCS Message:

Order does not contain drill data points

Explanation:

Incoming file is requesting job be drilled at edger without sending drill data

Severity Level:

Medium

Results:

No calculation provided, warning on ticket

Sources:

Missing drill data locations in file and file is requesting FCS to provide drill info

Corrective Actions:

1) Missing drill data in source file (library)

2) Run on non-FCS edger and apply drill points

3) LMS system error – call technical support

Several codes relating to “FLAT” frame/edge types are not detailed here. Those types are used in Europe and infrequently apply to the ELOA labs. For reference, those code numbers are; 5980, 5981, and 5982. Should any of these codes appear on a work ticket, please notify FCS Support (OTG).

General Errors:

Code:

1900

 

Frame Type:

All

FCS Message:

OMA file is not valid

Explanation:

FCS received an invalid DCS (oma) file

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support

Code:

1902

 

Frame Type:

All

FCS Message:

OMA file missing trace data

Explanation:

Incoming file from LMS does not contain a tracing

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support

Code:

1903

 

Frame Type:

All

FCS Message:

Trace data in OMA file is corrupt

Explanation:

Something is incorrect in the trace file sent from LMS

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

1904

 

Frame Type:

All

FCS Message:

OMA file has bad Z format

Explanation:

Format of the Z-data is unreadable or incorrect

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

1908

 

Frame Type:

Full Rim

FCS Message:

OMA file missing wrap angle        

Explanation:

Missing calculation component required for FCS

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Possible bad configuration at tracer (not sending data)

Corrective Actions:

1) Validate tracer output configuration

2) LMS system error – call technical support


Code:

1909

 

Frame Type:

All

FCS Message:

OMA file missing 3D trace data

Explanation:

FCS expects either FCRV (frame curve) or Z-data (ZFMT)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

Possible bad configuration at tracer (not sending data)

Corrective Actions:

1) Validate tracer output configuration

2) LMS system error – call technical support


Code:

1910

 

Frame Type:

All

FCS Message:

OMA file missing circumference data

Explanation:

Missing required component in file

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Possible bad configuration at tracer (not sending data)

Corrective Actions:

1) Validate tracer output configuration

2) LMS system error – call technical support


Code:

1913

 

Frame Type:

All

FCS Message:

Traced on non-FCS tracer

Explanation:

Traced on a non-FCS enabled tracer

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Tracer not configured / setup for FCS calculations

Corrective Actions:

1) Trace on appropriate FCS tracer

2) Run down non-FCS edger line

3) Add tracer (if valid type) to the FCS setting file (contact technical support)


Code:

1914

 

Frame Type:

All

FCS Message:

Order does not contain frame type

Explanation:

FCS did not receive the frame type (metal, plastic, rimless, etc) in the input file

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

1) Validate that frame type was included in the order. If not, then correct and try again

2) LMS system error – call technical support


Code:

1915

 

Frame Type:

All

FCS Message:

OMA file not found

Explanation:

FCS can not find the associated DCS (oma) file for the tray requested

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

1918

 

Frame Type:

All

FCS Message:

No DBL contained in file

Explanation:

Incoming file to FCS missing the DBL

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Tracing device sent 00.0 for DBL or Library file on LMS contains <null> or 00.0 for DBL

Corrective Actions:

1) Correct at tracer with valid DBL (if traced) or add the DBL to the shape library

2) LMS file system error – call technical support


Code:

1919

 

Frame Type:

All

FCS Message:

File is missing either vertical HT or PD

Explanation:

Incoming file is missing either the height (MF) or DPD

Severity Level:

High

Results:

No calculation provided, warning on ticket

Sources:

Incoming file missing expected data (depending on lens type)

Corrective Actions:

1) Correct order and submit again

2) LMS file system error – call technical support


Code:

3900

 

Frame Type:

All

FCS Message:

“description of error” (data filled in by specific error)

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

3901

 

Frame Type:

All

FCS Message:

Impossible to initialize FCS, Check FcsSettings

Explanation:

Missing data between LMS & RXCP (likely missing lens index)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

3902

 

Frame Type:

All

FCS Message:

Error during reading FxML

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

3903

 

Frame Type:

All

FCS Message:

OpticalLib: “detailed error” (data filled in by specific error)

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

1) Check work ticket for “convex” rear curves first – FCS will not calculate double convex lenses

2) Run on non-FCS edgers

3) LMS system error – call technical support


Code:

3904

 

Frame Type:

All

FCS Message:

CalculLib: “detailed error” (data filled in by specific error)

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support


Code:

3908

 

Frame Type:

All

FCS Message:

“OutOfBounds” (data filled in by specific error)

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

The shape is out of the lens. Can be linked to DEC, or bad lens diameter data

Corrective Actions:

LMS system error – call technical support


Code:

3909

 

Frame Type:

All

FCS Message:

Can not create OMA file

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS (digital lens failed to calc)

Corrective Actions:

LMS system error – call technical support


Code:

3910

 

Frame Type:

All

FCS Message:

Error during writing FxML

Explanation:

Communication problems between host (LMS) and RXCP (FCS)

Severity Level:

Very High

Results:

No calculation provided, warning on ticket

Sources:

LMS system input file to FCS

Corrective Actions:

LMS system error – call technical support

Simplified Codes, Numerical Order:

Code

Type

Frame Type Affected

Likely Source

Page

1900

ERROR

ALL

HOST SYSTEM

7

1902

ERROR

ALL

HOST SYSTEM

7

1903

ERROR

ALL

HOST SYSTEM, TRACER

7

1904

ERROR

ALL

HOST SYSTEM, TRACER

7

1906

ERROR

ALL

TRACER, HOST SYSTEM

4

1907

ERROR

FULL RIM

TRACER, DATA ENTRY

4

1908

ERROR

FULL RIM

HOST SYSTEM, TRACER

7

1909

ERROR

FULL RIM

HOST SYSTEM, TRACER

8

1910

ERROR

ALL

HOST SYSTEM, TRACER

8

1911

ERROR

RIMLESS

HOST SYSTEM

6

1913

ERROR

ALL

HOST SYSTEM, FCS SETTING

8

1914

ERROR

ALL

HOST SYSTEM, DATA ENTRY

8

1915

ERROR

ALL

HOST SYSTEM

8

1916

ERROR

ALL

DATA ENTRY, HOST SYSTEM

4

1917

ERROR

GROOVE

DATA ENTRY, HOST SYSTEM

5

1918

ERROR

ALL

HOST SYSTEM, TRACER

9

1919

ERROR

ALL

HOST SYSTEM

9

3900

ERROR

ALL

HOST SYSTEM, RXCP

9

3901

ERROR

ALL

HOST SYSTEM, RXCP

9

3902

ERROR

ALL

HOST SYSTEM, RXCP

9

3903

ERROR

ALL

HOST SYSTEM, RXCP

10

3904

ERROR

ALL

HOST SYSTEM, RXCP

10

3908

ERROR

ALL

HOST SYSTEM, RXCP

10

3909

ERROR

ALL

HOST SYSTEM, RXCP

10

3910

ERROR

ALL

RXCP

10

5900

WARNING

FULL RIM

LAB

2

5901

WARNING

FULL RIM

LAB, FCS SETTING

2

5902

WARNING

FULL RIM

DATA ENTRY, HOST SYSTEM

2

5903

WARNING

FULL RIM

LAB, FCS SETTING

2

5910

WARNING

GROOVE

LAB, FCS SETTING

3

5911

WARNING

GROOVE

DATA ENTRY, HOST SYSTEM

3

5920

WARNING

RIMLESS

LAB, FCS SETTING

3

5930

WARNING

FULL RIM

TRACER, FCS SETTING

1

5931

WARNING

FULL RIM

TRACER, FCS SETTING

1

5932

WARNING

FULL RIM

TRACER, FCS SETTING

1

5950

ERROR

FULL RIM

FCS SETTING

4

5951

ERROR

FULL RIM

FCS SETTING, LAB

4

5952

ERROR

FULL RIM

FCS SETTING

5

5960

ERROR

GROOVE

FCS SETTING

5

5961

ERROR

GROOVE

FCS SETTING, LAB

5

5962

ERROR

GROOVE

FCS SETTING

5

5963

WARNING

GROOVE

FCS SETTING

3

5970

ERROR

RIMLESS

FCS SETTING

6

5971

ERROR

RIMLESS

FCS SETTING, LAB

6

5972

ERROR

RIMLESS

FCS SETTING

6

5973

WARNING

RIMLESS

FCS SETTING

3

6900

WARNING

FULL RIM

LAB

1



To view and download these instructions as a PDF file, click on the following document image.