With RX-Universe it is possible to have a Thin Client session connecting from the outside via the Internet. It does require a few configurations that may require the local IT support to help with this.

The client will need this

  1. A Public Static IP Address or alternatively a Dynamic DNS Service that automatically updates to the Public IP (ie:WWW.DYNDNS.ORG)
  2. A Static IP Address on the RX-Universe Server
  3. Configure the Firewall/Router to forward port 5640 to the IP of the RX-Universe Server
  4. Also open Incoming out outgoing traffic on Firewall or the RX-Universe Server

 

 

In the example below we are assuming that the Public IP provided by the ISP is 142.166.201.203 and that the RX-Universe Server is setup on a static IP of 192.168.1.50

 