Introduction

This document provides instructions for marrying a frame to a tray.

Procedure

From the Optifacts main menu:

Type 7 - Tray Track and press enter.

Type 7 - Station Assignment and press enter.

The Station Assignment screen displays.

  • Type the Frame Marry station number and press enter.
  • Type tray number and press enter.

You will see the message on the following diagram.

  • Scan the frame bag to continue. This is the trace99 bar code that is on the bag label.

A successful scan will display a confirmation message.

Error Messages

The following are some of the error message you may see on screen:

Tray does not match the bag bar code.

Job is a Frame to Come, the frame has arrived and has been assigned to a bin.

Job is a Frame to Come and the frame has not arrived.

Frame has already been married to the tray.


Job is not a frame to come.