to be released 19 November 2019

Order Entry

When using DATA traces, the program was not settings the frame type on the order based on the frame. This has been corrected.

Digital Surfacing

Support for decentered designs on uncuts has been added for vendor “Comes” using the BCERIN/UP labels.

For A2Vision, Crossbows, and Signet digital vendors only, if decentration is not specified on an uncut job, Rx-Universe will now send SBSGIN=? and SBSGUP=? instead of SBSGIN=0 and SBSGUP=0.  This allows defaults to be set on the digital calculator that won't be over-ridden by receiving a 0 value from Rx-Universe

Devices

When using a SatisLoh ART blocker, if the order called on the blocker had ELLH values that were less than the CRIB values, the chosen block diameter could be too large and the generator cuts into the block.