Rx-Universe can be set up to automatically select a regular or short progressive design, based on the SEGHT of the job.

There are two steps to this:
1. set up the designs with the appropriate minimum seg height

2. set up an alias record to go from the regular progressive to the short

An example will illustrate this. Consider a Shore ES (regular) progressive, and a Shore ESM (short) progressive.

Set up the ES progressive with a minimum segment height, say 20, and set the “Action” field to Y, which tells Rx-Universe to consider other designs if the entered seg height is less than 20mm.

Set up the ESM with the minimum seg height for that design, and set the Action field to “E”, so that Rx-Universe will throw an error if a segment height of less than the specified value is entered: