Define Block Pieces and Selection Rules

Nucleo/ART blocks have some additional parameters that must be set up in Rx-Universe.  The block and blank together look as follows:

Of the above fields, the _BLKDM (physical diameter of the block), _BLKRD (radius of curvature of the inside of the block), and _BLKCEHI (height of the block piece) must be set in Rx-Universe.  The _LBLHI and RNGH values will be calculated by the blocker, based on the difference in curvature between the block piece and the front surface of the blank, and the amount of adhesive used, and sent back to Rx-Universe.  These values will then be used when communucating with other devices.

The particular block pieces that are available, with their characteristics, and rules on when to use the block, must be set up in Rx-Universe, under "Setup", "System Settings", then the new "Nucleo" tab.

The ART and Nucleo blocks can be set up separately.  For each block piece:

  • the "Text" column specifies the text that will be printed on the work ticket. 
  • the "radius" field is the radius curvature of the inside block piece (_BLKRD)
  • the "min r" field is the minimum radius of curvature of the blank for this block piece
  • the "max r" field is the maximum radius of curvature of the blank for this block piece
  • the BLKCEHI column is the height of the block
  • the "diam" field is the physical diameter of a new (unused) block piece (_BLKDM)

To pick a block piece, the "true curve" of a blank will be converted to radius of curvature, that radius of curvature compared to the "min r" and "max r" values for each block, and the block picked that includes the radius of curvature of the blank.

For example, if a blank has a true curve of 5.92, in 1.53 index, that blank has a radius of curvature of 89.527.  Comparing that to the "min r" and "max r" of the block list, block piece 5 will be selected.

Select Block Pieces by Diameter

Because ART and Nucleo blocks can be cribbed (the cribbing process actually cribs the block down, as well as the blank), and the block pieces can be re-used, a lab will quickly find itself with many block pieces of different diameters.  To re-use, the blocks can be grouped into "groups" by diameter.  The number of groups and the sizes of each group can be defined by the lab.

Selection of these blocks of different diameters is done by means of the "diameter selection" grid:

Blocks will be physically divided into these groups after use, based on how small they were cribbed for the last job run.  In the example above, we have 5 groups of blocks; the first group will contain blocks that are up to 55mm in size; the second group up to 60mm in size, etc.  :

The first group has blocks up to 55mm large, can be used for any job requiring up to a 55mm crib

 

The second group has blocks bigger than group 1, up to 57mm; the third group up to 65mm, the fourth up to 70mm, and the last group is made up of full-size blocks (75mm).

 

Selecting ART or Nucleo blocking system-side, by material, by lens style, by order

The system default for blocking method / block size can be set on the "Setup", "System Settings", "Devices" tab.  The new options are:
"U" - Nucleo blocking
"A" - ART blocking

 

The blocking method can also be specified for specific materials or specific lens styles:

Nucleo or ART blocking can also be specified for a particular order:

When Nucleo or ART blocking has been requested, whether system-wide, by material, lens style, or order, the work ticket will show the block to be used:

 

The "BP1" in this case indicates that "Block Piece 1" should be used (the text comes from the text field on the System Settings screen), and the 65 indicates that a block from the 65mm group should be used.

 

 

 