Search Optifacts User Documentation
Table of Contents (on this page)
Introduction
This document provides instructions for setting up the Commercial Branding Tool (CBT) function allowing the ability to use a branded name to produce a digital lens.
Procedure
Job Data Definition
You must set up the following Job Data Definition before proceeding.
From the Optifacts main menu:
Select Option 3 – Editor Utilities and press Enter.
Select Option 6 – Configuration Editor and press Enter.
Select Option 7 – Edit Job Data Definitions and press Enter.
The Prompt Configuration for Miscellaneous Job-Related Data window is displayed.
- Enter all the data, as shown in the example below, pressing Enter past each field.
- Press Escape to save the data
- Press “E” to exit the screen.
Now you may proceed to set up the CBT screens:
CBT Setup
From the Optifacts main menu:
Select Option 3 - Editor Utilities and press Enter.
Select Option 14 - Commercial Brand Editor and press Enter.
The Commercial Branding (CBT) Menu is displayed.
Step 1 - CBT Name
Select Option 1 - CBT Master Editor and press Enter.
The Commercial Brand Master Editor window is displayed.
- Press "A" to add a new record.
An entry in this table is required for every CBT lens.
- Enter the CBT name to describe the lens name or design.
- Enter the CBT family to describe the family name where you can group familiar lenses.
- Add any comments if desired.
- Enter the calculation engine if applicable.
- Press Escape to save the data.
- Press “E” to exit.
Examples: Notice in the following two diagrams, that two lens designs are using the same family.
Step 2 - Order Entry Parameters
From the Commercial Branding (CBT) Menu:
Select Option 2 - CBT Order Entry Editor and press Enter.
The Commercial Branding Order Entry Control Editor is displayed.
- Press “A” to add a new record.
- Enter the Commercial Brand Name.
The Commercial Brand Name must be an exact match to the name created in the CBT Master Editor.
- Enter all the other required fields.
If a field is left blank, the system looks at all codes described by the field name. Along with the Commercial Brand Name, some of the usual fields to enter are Lens Type Code, Lens Color/Coat Coat, and Lents Material Code.
- Press Escape to save the data.
- Press “E” to Exit.
Example: Notice that in the following diagram, there are 44 rows for one design name. That is because each material and color available for that lens design has an entry. If you entered this particular lens design and left the material and, or color fields blank, then all materials and, or colors in the database would show up in order entry, causing issues if the material and or color does not exist. By narrowing down the materials and or colors, then the order entry operators would only be able to select those specified in this table. Something to remember in this case is that every time a new material and or color becomes available, you need to add it so that order entry can see it in the selection list.
Step 3 - Job Data Triggers
The field names must be defined in the Job Data Definition Table (Menu 3-6-7). Refer to the Job Data Definitions and Triggers section from the User Documentation Index for details on setting up definitions and triggers. Order Entry will be prompted to enter the required job data.
From the Commercial Branding (CBT) Menu:
Select Option 3 - CBT Job Data Fields Editor and press Enter.
The Commercial Branding Job Data Triggers window displays.
- Press “A” to add a new record.
- Enter the Commercial Brand Name.
The Commercial Brand Name must be an exact match to the name created in the CBT Master Editor.
- Enter all the other required fields.
- Press Escape to save the data.
- Press “E” to Exit.
Examples: Notice that in the first diagram that the entry is specific to material TLT, but the second diagram applies to the same lens design for all materials. (Material code field is blank).
Here are a few more examples of job data triggers. There are various CBT Job Data Triggers. This document may not contain the full list of available options. Please contact Optifacts Support as others may be needed.
Step 4 - Field Validations
Use field validations to define restrictions for the specified lens design, materials and, or colors.
From the Commercial Branding (CBT) Menu:
Select Option 4 - CBT Field Validation Editor and press Enter.
The Commercial Branding Field Validation Editor window is displayed.
- Press “A” to add a new record.
- Enter the Commercial Brand Name. The Commercial Brand Name must be an exact match to the entry in the CBT Master Editor.
- Enter all the other required fields.
- Press Escape to save the data.
- Press “E” to Exit.
Examples: Notice that in the first diagram, there is a sphere power restriction of -10.00 to 6.00 for type VXY material P, but in the second diagram, the sphere power restriction is -12.00 to 8.00 for the same lens type VXY with material TL.
Step 5 - Invoice Mapping
Use invoice mapping to define how you want to represent certain fields on the printed invoice.
From the Commercial Branding (CBT) Menu:
Select Option 5 - CBT Invoice Mapping Editor and press Enter.
The Invoice Commercial Branding Editor window is displayed.
- Press “A” to add a new record.
- Enter the Priority Number and press Enter.
The priority number represents the hierarchy in which the system looks at matching records.
- Enter the Account Number "0" (zero to represent all accounts) and press Enter.
- Enter the Commercial Brand Name. The Commercial Brand Name must be an exact match to the entry in the CBT Master Editor.
- Enter all the other required fields.
Data on the left side (incoming fields) represents what gets entered, and data on the right side (Invoice representation) indicates what prints on the invoice.
- Press Escape to save the data.
- Press “E” to Exit.
Example: In the following diagram, we represent the material code TVX on the printed invoice as TREXA.
Step 6 - Product Mapping Codes
Product mapping is required if mapping the CBT product or any other Optifacts SKU to an external calculator.
From the Commercial Branding (CBT) Menu:
Select Option 6 - CBT Product Code Editor and press Enter.
The Product Code Editor window is displayed.
- Press “A” to add a new record.
- Enter all the other required fields.
- Press Escape to save the data.
- Press “E” to Exit.
Example: Optifacts SKU mapped to the SCG calculator.
Step 7 - Service Code Mapping
Service code mapping is required if mapping CBT Pricing Options to an external calculator.
From the Commercial Branding (CBT) Menu
Select Option 7 - CBT Product Services Editor and press Enter.
The Product Code Editor window is displayed.
- Press “A” to add a new record.
- Enter all the other required fields.
- Press Escape to save the data.
- Press “E” to Exit.
Example: Optifacts Pricing Option mapped to the SCG calculator.
Step 8 - Modify Product Codes
New field “Value Entered” added to the mod_prod_codes table that allows three values to assign a product code:
- P - Job data field need only be present.
- Y - A value is necessary.
- N - Not applicable.
From the Commercial Branding (CBT) Menu:
Select Option 8 CBT Product Code Modifier Editor and press Enter.
The Product Code Modifier Editor is displayed.
- Press “A” to add a new record.
- Enter all the other required fields.
- Press Escape to save the data.
- Press “E” to Exit.
Example:
Step 9 - Corridor Length Editor
This editor allows set up of fitting heights and corridor lengths by CBT Description.
From the Commercial Branding (CBT) Menu:
Select Option 9 CBT Corridor Length Editor and press Enter.
The Product Code Modifier Editor is displayed.
- Press “A” to add a new record.
- Enter all the other required fields.
- Press Escape to save the data.
- Press “E” to Exit.
Example: Notice in the following diagram that there are 32 records for this particular CBT.
Order Entry Examples
CBT Selection
If your lab is using CBT then the CBT selection window is displayed
Make your selections following the prompts through each window.
- 0 - Not a CBT. If you choose this option, the window closes, and the active cursor moves to the Rx window.
- 1 - Pick CBT by Name. If you choose this option, a list displays, and you make your selections from the available options in the list.
- Enter the number of the appropriate lens design and press Enter to continue.
- 2 - Enter CBT by Name. If you choose this option, you can scroll through the list by using your up and down arrow keys to highlight the appropriate lens design.
- Press Enter to select the highlighted lens.
In our examples below, we have chosen option 1 - Pick CBT by Name.
Once you pick a CBT name (as shown in the diagram below or option 1 above), the system asks you to make a selection from the CBT Family Names.
The number of selections you get asked to make is dependent on the CBT configuration.
Make your selection and press Enter.
Then, the system asks you to make a selection from the CBT Description Names.
- Make your selection and press Enter.
If you need to view more options, type 999 and press Enter to move to the next list.
- After making all your selections, continue to process the order as usual.
To view and download these instructions as a PDF file, click on the following document image.