Anchor | ||||
---|---|---|---|---|
|
Search Optifacts User Documentation
Live Search | ||||
---|---|---|---|---|
|
Table of Contents (on this page)
Table of Contents | ||||||
---|---|---|---|---|---|---|
|
Introduction
This document provides instructions for enabling the Tilt Compensation custom configurations to allow compensation for a progressive prism tilt induced at the blocker.
Procedure
From the Optifacts main menu:
Select Option 3 – Editor Utilities and press Enter.
Select Option 6 – Configuration Editor and press Enter.
Select Option 6 – Edit Custom Configuration and press Enter.
The Custom Configuration Editor displays.
- Press “Q” to Query.
- Enter any relevant data and press Escape to perform the search.
If the table does not exist:
- Press “A” to add a new record.
- Enter all the information, as shown in the example below.
- Press Escape to save the data.
- Press “E” to exit.
Examples:
Below are examples of the entries that you can use. When running a progressive, the ofdemon program looks for entries with the Calling Program field value of “TILT COMP.”
It first looks for an entry with the Field Name of “TYPE-MAT” (the example below is PAN-PX). If found, the value in the Float Setting field is for tilt comp, base up in diopters.
If it does not find a record, it searches for Field Name of “TYPE” (the example below is PAN). If found, it uses the float value.
If not found, it searches for the Field Name of “DEFAULT” ( as shown in the example below).
If it does not find a record, there is no tilt compensation done.
To view and download these instructions as a PDF file, click on the following document image.
View file | ||||
---|---|---|---|---|
|