Introduction

This document provides instructions for setting up the tray tracking stations that can be used to turn off or turn on a lite-up, on a job that is in process without having to recall and edit.

Procedure

Tracking Station setup

From the Optifacts main menu:

Type 7 - Tray Track and press enter.

Type 12 - Tray Track Configuration and press enter.

Type 2 - Sub-Master Station Number Setup and press enter.

The Sub-Master Station Number Setup screen displays.

Turn any Lite-up On or Off Without Recalling

through

Through Order Entry

The following setup will allow you to turn on or off a lite-up without having to recall the job.

  • Type Q for query.

Search for the sub-master station numbers or descriptions as determined by your system administrator.

  • Enter the predetermined number in the master station number field, or enter the predetermined number or description in the applicable fields.

  • Press escape to show the results.

If the entries do not exist:

  • Press A to add a record.

Note: The Master Station must be set up before adding a Sub-Master Station.

  • Enter the following data, as shown in the following diagrams, pressing enter past each field.
    • Master Station Number

    • Sub-Master Station

    • Station Description

      • Setup as LUON and LUOFF
    • Station Type - Press enter to accept N as the default entry.

      • N - Normal
    • Station Priority - 0 is the default priority number
    • Lite-up Number
      • Leave this field defaulted to 0.
    • Delay station
      • Enter N
    • Interface Port - Leave Blank
    •  After Breakage - Set to N.
  • Press escape to save the data.

  • Type E to exit the screen.

Stop Jobs at Mailout that Have

the

a Specified Lite-up

assigned

Assigned in the

sub

Sub-station, but

have

Have not Passed Through

the

that Station.

The following setup will stop jobs at mailout that have the specified lite-up assigned in the tracking station, if they have not passed through that station.

  • Type Q for query.

Search for the sub-master station numbers or descriptions as determined by your system administrator.

  • Enter the predetermined number in the master station number field, or enter the predetermined number or description in the applicable fields.

  • Press escape to show the results.

If the entries do not exist:

  • Press A to add a record.

Note: The Master Station must be set up before adding a Sub-Master Station.

  • Enter the following data, as shown in the following diagrams, pressing enter past each field.
    • Master Station Number

    • Sub-Master Station

    • Station Description 

      • Setup as LUON or LUOFF with dash ( - ) and the lite-up short description
    • Station Type - Press enter to accept N as the default entry.

      • N - Normal
    • Station Priority - 0 is the default priority number
    • Lite-up Number
      • Enter the desired lite-up number that you want to trigger on or off with this sub-master station. This is the lite-up number seen on the pricing options page in Rx Order Entry.
    • Delay station
      • Enter N
    • Interface Port - Leave Blank
    •  After Breakage - Set to N.
  • Press escape to save the data.

  • Type E to exit the screen.

In the following example we are using the the POLISH lite-up.

Here is another example where the job would have to pass through the IN COATLAB lite-up before it can be mailed out.

Station Assignment

Once the stations are setup, the user may simply track a tray to the "LUON" or "LUOFF" stations through the station assignment screen.

From the Optifacts main menu:

Type 7 – Tray Track and press enter.

Type 7 – Station Assignment and press enter.

The Station Assignment Screen displays.

  • Type the station number as assigned in the Tray Track Sub-Master and press enter.
  • Type the tray number, job number or invoice number and press enter.
  • You will then be asked to enter a lite-up number.

A confirmation of the change will display on screen.