Introduction
This document provides instructions to set up a routing rule that will stop a job from automatically routing.
Procedure
Step 1 - Setup Do not Route Lite-up
From the Optifacts main menu:
Type 3 - Editor Utilities and press enter.
Type 4 - Pricing Database Editor and press enter.
Type 4 - Lite-up Options and press enter.
Type 1 - Add/Edit Lite-up Options and press enter.
The Add/Edit Lite-up Options screen displays.
- Type an * (asterisk) in the Valid for Glass, Plastic, Both field and press enter.
- Type the Lite-up number and press enter. (This is the lite-up number that you see on the pricing options screen in order entry.)
The rest of the screen will be displayed.
- Enter all the data as shown in the following diagram, pressing enter past each field.
- Are the entries correct (Y/N)?
- Type Y to confirm
- Type N to return to the form.
- Press Escape to exit.
Routing Rule
Step 1 - Route Destination Editor
From the Optifacts main menu:
Type 3 - Editor Utilities and press enter.
Type 11 - Job Routing Menu and press enter.
Type 11 - Route Destination Editor and press enter.
The Job Routing Destination Control Manager screen displays.
- Type A to add a new record.
- Create a new Routing Destination as shown in the following diagram.
- Destination Site - internl
- Out-Going File Format - OPTI2.8
- Transmit Protocol - I
- Destination directory - /u/optifacts
- Press Escape to save the data.
- Type E to exit.
Step 2 - Route Conditions Control Editor
- Type 9 - Route Conditions Control Editor and press enter.
The Job Routing Condition Control Manager displays.
- Type A to add a new record.
- Create an entry as shown in the following diagram.
- Condition ID - DO NOT ROUTE
- Destination Site - internl
- Type N in the Force Uncut field and press enter
- Type N in the Dispatch Job field and press enter.
- Press enter down to the Clear alll Lite-ups field.
- Type N
- Press Escape to save the data.
- Type E to exit.
Step 3 - Route Reason and Control Editor
- Type 8 - Route Reason and Control Editor and press enter.
The Job Routing Reason and Control Manager displays.
- Type A to add a new record.
- Enter all the data as shown in the following diagram, using your own priority number as decided by your lab.
- Priority - Number must be a higher number than the other rules you have where you do not want the job to hit those rules first.
- Condition ID - Must be the same as setup in menu 3-11-9 Job Routing Condition Control Manager.
- Comments - A description of what the rule represents.
- Press Escape to save the data.
- Type E to exit.