Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
top
top

Search Optifacts User Documentation

Live Search
spaceKeyOPPUB
placeholderEnter search keyword(s) here


Table of Contents (on this page)

Table of Contents
indent20px
styleBullet

Introduction

This document provides instructions to set up a routing rule that will stop a job from automatically routing. 

Procedure

Step 1 - Setup Do not Route Lite-up

From the Optifacts main menu:

Type 3 - Editor Utilities and press enter.

Type 4 - Pricing Database Editor and press enter.

Type 4 - Lite-up Options and press enter.

Type 1 - Add/Edit Lite-up Options and press enter.

The Add/Edit Lite-up Options screen displays.

  • Type an * (asterisk) in the Valid for Glass, Plastic, Both field and press enter.
  • Type the Lite-up number and press enter. (This is the lite-up number that you see on the pricing options screen in order entry.)

The rest of the screen will be displayed.

  • Enter all the data as shown in the following diagram, pressing enter past each field.
  • Are the entries correct (Y/N)?
    • Type Y to confirm
    • Type N to return to the form.

  • Press Escape to exit.

Routing Rule

Step 1 - Route Destination Editor

From the Optifacts main menu:

Type 3 - Editor Utilities and press enter.

Type 11 - Job Routing Menu and press enter.

Type 11 - Route Destination Editor and press enter.

The Job Routing Destination Control Manager screen displays.

  • Type A to add a new record.
  • Create a new Routing Destination as shown in the following diagram.
    • Destination Site - internl
    • Out-Going File Format - OPTI2.8
    • Transmit Protocol - I
    • Destination directory - /u/optifacts
  • Press Escape to save the data.

  • Type E to exit.

Step 2 - Route Conditions Control Editor

  • Type 9 - Route Conditions Control Editor and press enter.

The Job Routing Condition Control Manager displays.

  • Type A to add a new record.
  • Create an entry as shown in the following diagram.
    • Condition ID - DO NOT ROUTE
    • Destination Site - internl
    • Type N in the Force Uncut field and press enter
    • Type N in the Dispatch Job field and press enter.
    • Press enter down to the Clear alll Lite-ups field.
      • Type N 
  • Press Escape to save the data.

  • Type E to exit.

Step 3 - Route Reason and Control Editor

  • Type 8 - Route Reason and Control Editor and press enter.

The Job Routing Reason and Control Manager displays.

  • Type A to add a new record.
  • Enter all the data as shown in the following diagram, using your own priority number as decided by your lab.
    • Priority -  Number must be a higher number than the other rules you have where you do not want the job to hit those rules first.
    • Condition ID - Must be the same as setup in menu 3-11-9 Job Routing Condition Control Manager.
    • Comments - A description of what the rule represents.
  • Press Escape to save the data.

  • Type E to exit.