Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Hoya digital requires the customer to run a "middleware" LDS Client. This "middleware" LDS client will receive the JOB#.LDS from Omics RxUniverse and convert and create a temporary copy of the original .LDS file (IE: It will translate the JOB.LMS to JOB~00000.ODS). Once this completed the LDS client will perform calculation via a cloud calculator where the results will be sent back and the JOB#.LMS will be added to the defined directory. (note: Hoya will provide you with instructions on how to define the LMS/LDS directory within the HOYA LDS middleware)

The Hoya LDS "middleware" does not properly move the .SDF file in the location initially define in OmicsRxUniverse. To fix this In Omics you will need to add the .SDF in the "Move SDF file from folder". This will cause Omics RxUniverse to move the .SDF file in the location define in the "Location of SDF files from digital surface" field.

...

4) Set up the lens style(s) needed, per the instructions that follow.

Designs (LNAM codes)

CodeNameLNAMPucksComments
ID, IDCRiD-Lifestyle457uses IDPK pucksnot available in 170, 174 - two different lens style codes for different "degression" selection
 iD-Lifestyle CD458uses IDCDPK pucksnot available in 170, 174 - two different lens style codes for different "degression" selection
 iD-Lifestyle-Harmony962uses IDPK pucksnot available in 170, 174 - two different lens style codes for different "degression" selection
 iD-Lifestyle-Clarity963uses IDPK pucksnot available in 170, 174 - two different lens style codes for different "degression" selection
 iD-Lifestyle-CD-Harmony964uses IDCDPK pucksnot available in 170, 174 - two different lens style codes for different "degression" selection
 iD-Lifestyle-CD-Clarity965uses IDCDPK pucksnot available in 170, 174 - two different lens style codes for different "degression" selection
ECPIQSummit ECP IQ581uses SUMMIT pucks 
CDIQSummit CD IQ582uses SUMMCD pucks 
AMPIQAmplitude IQ583uses Amplitude pucks 
AMPMIQAmplitude Mini IQ584uses Amplitude mini pucks 
 SV BF IQ  design was listed from Hoya but with no documentation
ARY11Array 11mm832uses SV pucks 
ARY13Array 13mm833uses SV pucks 
ARY15Array 15mm834uses SV pucks 
ARY17Array 17mm835uses SV pucks 
AMPBSArray Amplitude836uses SV pucks 
AMPMBSArray Amplitude Mini837uses SV pucks 
SYNC5Array Sync5838uses SV pucks 
SYNC8Array Sync8839uses SV pucks 
TCTBS4Array Tact Backside 40840uses SV pucks 
TCTBS6Array Tact Backside 60 uses SV puckscoming soon as of Feb 2015

 

LMATID Codes

(These codes are set up in table HOYA, you can download this table by importing this table using "Import From Web" in the VCA label tables).

MaterialIndexLMATID
CR391.4982
CR39 Polarized1.49810
Transitions1.50120
Poly1.5864
Poly Polarized1.58630
Poly Transitions1.58636
Trivex1.53053
Trivex Transitions1.53054
Trivex Polarized1.530169
1601.59519
1671.6641
167 Transitions1.6649
1701.7042
1741.7451

 

Setting up Hoya designs

LifeStyle

...