Beginning with version 6.45.00, Rx-Universe allows labs to use work tickets designed with Satisloh's LOHreport program.
...
RXNM - order number (use this instead of JOB, as JOB has specific meanings within the VCA convention
_RXNMEYE - returns RXNM + 0 at the end for the right eye and 1 at the end for the left eye
_EYERXNM - returns 0 at the start for the right eye and 1 at the start for the left eye + RXNM
...
_REMAKE_TEXT - returns a text message "REMAKE:" if the order is a remake
_REMAKE_REASON - returns the description of the remake reason code if the job is a remake
_FREEFORM - returns a text message "FREEFORM" if the order is a digital job
...
SPH - sphere power as entered
_SPHNEG - returns the sphere in negative cylinder format
_LDSPH - returns compensated sphere (or Rx sphere if no compensation)
_LDDRSPH - returns compensated sphere at the distance reference point (or Rx sphere if no compensation)
CYL - cylinder as entered
_CYLNEG - returns the cylinder in negative cylinder format
_LDCYL - returns compensated cyl (or Rx cyl if no compensation)
_LDDRCYL - returns compensated cylinder at the distance reference point (or Rx cylinder if no compensation)
AX - cylinder axis as entered
_AXNEG - cylinder axis in negative cylinder format (transposed if necessary)
_LDAX - returns compensated axis (or Rx axis if no compensation)
_LDDRAX - returns compensated cylinder axis at the distance reference point (or Rx cylinder axis if no compensation)
ADD - add power
_LDADD - returns compensated add power (or Rx add if no compensation)
...
_LOHPRVM - returns the amount of prism to be blocked/generated in angular degrees
_LOHPRVA - returns the angle of prism to be blocked/generated
_SVAL2 - returns the SVAL (EV) for the lens with 0.1mm added for surface tape
SLBP - returns slaboff prism as diopters in material index (chiral field)
SLDRP - returns the slaboff reading drop, in mm, as a chiral field
_LOHSLBP - returns the slaboff prism in angular degrees, as a chiral field
_LOHSLBPTXT - returns the slaboff prism, which eye and drop value as a chiral text
CTHNP- returns the minimum edge thickness at the crib diameter of the lens. Today this is returned only for toric lenses, not digital.
...