When the lines are not checked, the OMA program verifies that the required coatings are either on the lenses from the factory, or that the associated service required field is set to Done. These checks are done independently for each eye.
...
RxServer Options:
Send results to RxServer - this selects whether the job order number or tray number is used as the job number in RxServer. RxServer supports only one number as the reference number, so only one of these numbers can be sent from Rx-Universe. If devices are attached to RxServer, this will be the number used at devices to request the job.
Get jobs from RxServer - If checked, Rx-Universe maintains a file of orders to be interfaced with RxServer.
...
Drill point edge tolerance - This value is used when checking the drill points to se if they are inside the trace. This value represents the amount of lens that must be present between the end of a drill point and the edge of the cut lens in order for the drill point to validate. This value is only used to display a warning when modifying drill points and does not stop the user from accepting drill points that may be outside the cut lens.
...
ELLH Options:
ELLH thickness breakpoint - This is the minimum cribbed thickness value that will trigger elliptical cribbing. If a lenses cribbed thickness is below this threshold, then ELLH will be calculated for the lens.
ELLH maximum difference - This value contains the maximum allowable difference from the crib diameter that’s allowed to be saved. When the ELLH is calculated, its value cannot be less than (CRIB Diameter - Max Difference).
ELLH maximum percentage - This value contains the maximum allowable percentage difference from the crib diameter that’s allowed to be saved. When the ELLH is calculated, its value cannot be less than (CRIB Diameter * Max Percentage).
...