Surface Radius Smaller Than Tool Radius
This error can appear at Version 15.0.3.0 of the Satisloh generator when it detects that software does more critical checking of the tools, so this error can occur when the radius of the surface is smaller than the tool radius. :
A very strong curve as follows:
Can result in the following error
The following suggestions to fix this issue have been suggested by Satisloh:
...
At the macro management on the Generator you will find the surface smoothing, options. Here you select from off to light, medium or strong, as well as further refining the macros from -5 up to +5. Negative values make the test less sensitive, positive value more sensitive.
:
3. On Blended bifocal designs if none of the above work, try using a larger _BLEND value (for Crossbows only). This will give a smoother transition between distance and segment areas and may eliminate the issue.