Rx-Universe can be setup to communicate with the LS2208 barcode scanners.  The device parameters screen is setup as follows:

Set the Device Manufacture to "Symbol" or "Motorola", then set the device type to "LS2".  The baud rate is set to 9600, Databits to 8, Stopbits to 1, with Parity set to None, and no flow control.   When setting up the LS2208, make sure that it is programmed to send a "CR" carriage return after the scan.

The LS2208 interface is designed to accept both tray number and order number scans; any scan that is greater than 5 digits will be interpreted automatically as an order number.   

If the device session is set up with a "Job Track ID" that is a set as a "Global" station, any scans in the "99nnn" range will be interpreted as either a new station identifier or an operator identifier, depending on the setup of the "nnn" station associated with the "99nnn" scan.