to be released….

Customer

The Accounts receivable customer maintenance screen, “statement” tab has 2 new fields added to it to allow for customer specific messages to be printed on the printed statements. All the Rx-Universe supplied statement formats have the ability to use these new customer messages.

Customer Service

When viewing “Job history” or “Inventory transactions”, the time display is incorrect for records that have a time within the ”00” or “12” hour ranges. This was a display issue and has been resolved.

Pressing <F5> on an order in the customer service grid will display the job history screen for the highlighted order

Pressing <F12> on an order in the customer service grid will prompt for breakage entry for the highlighted order

Pressing <CTRL>-<N> on an order in the customer service grid will prompt for order note entry for the highlighted order

The number of breakages on an order has been added to the customer service grid:

Devices

When trying to call an orphaned trace on a OMA edger, the device interface always returned “WONF” (order not found). This has been resolved.

When the VCA device interface auto-attaches a trace to an order that has SEGDHT values in it, if the order was for a Single Vision prescription, the resulting Vertical decentration was being placed in the SEGHT field instead. This has been resolved.

The VCA device interface has been modified to not store the GPRVM and GPRVA labels when they are returned from a digital vendor, if the value they contain is “?”.

Frame Inventory

When the frame inventory module is active, check to see if access to the frame inventory is ok when entering Rx-Universe, if not display a warning message so the issue can be addressed. The same frame inventory access check is done after the user has accessed 5 menu entries, this will warn the user that the frame inventory is not available while doing various tasks within the Rx-universe system.

Orders

When saving an order that has been calculated, if the order had errors when calculating, display a warning message that says the order is still un-valid before saving it.

When modifying an order, if the chosen blanks are changed via the “F6/Blanks” screen, you could save the order as valid without re-calculating it. This would cause issues on the devices. The order modify screen has been changed to request a re-calculation of the job before allowing it to be saved when the selected blanks are changed.

Printing User defined documents

RxTicket has been updated to ensure the PDF is fully written before the done file is created, fixing rare situations where the PDF was corrupted while copying over thin client sessions.