to be released …..

Devices

The VCA device interface has been modified to only calculate the Loh Prism for a valid eye. One-eye jobs were calculating both eyes and storing an incorrect value for the side that wasn’t being manufactured.

Shipping

The shipping program has been modified to automatically delete the temporary Job Completion file upon exiting (JOBCOMPL.##).

User-defined Work Tickets

Several enhancements have been made to the user-defined work tickets.

  1. Support for colours has been added for text - the following colours are now supported (as demonstrated in a ticket produced with this update):

    The top right box is “Cream”, which is faint but perhaps desired on coloured work ticket paper.

  2. Background colours are also supported, and have been modified to recognize the “Show box only if value exists” checkbox - this allows multiple background-only boxes to be placed in the same location on the work ticket, and displayed based on different user-definable VCA tags. An example could be different coloured boxes indicating different AR coatings.

  3. Support for extended character sets has been added; this allows characters outside the default Windows-1251 character set (such as the € character, or oriental characters) to be displayed on the work ticket.

  4. These changes necessitated a change in the behaviour of the “default” values in the LOHreport program. When setting up a ReportBox item, on the following screen:

    anything entered in the “Value” box will now be printed if the label is not applicable for a given job. Therefore, this value should normally be left blank. This is a change in behaviour from versions of Rx-Universe prior to version 7.39. Note that this COULD be useful when wanting to set a field to a value to be printed in the absence of a field - for example, a default might be set to “No Coating” if such a message were desired in the absence of a coating value.

Frame Trace Import

To facilitate import of frame traces from VisionStar to Rx-Universe, the VEN label is now considered equivalent to FMFR, and LIB is now considered synonymous with FRAM.