Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Cribbing tells a generator to reduce the blank size while keeping the round blank shape.  This is to make a lens, once its surfaced, easier to manage in the edging devices.

Elliptical cribbing tells a generator to crib a lens in an oval, rather than round, shape.  This can be beneficial in reducing the thickness at the crib edge on high plus jobs, and reducing problems cutting into the soft tool on modern polishers.

Cribbing (CRIB)

The amount of cribbing that a blank requires is determined by the various calculators.  When a generating device asks for CRIB, the value of the crib sent is determined by the "Cribbing Allowance" settings in the device parameters screen.

Image Added

The cribbing allowance is added to the calculated crib and sent to the device.  If the calculated crib plus the allowance is less than the 'Minimum Diameter" setting, then the "Minimum Diameter" is sent as the crib value.   

The Crib value can be suppressed if so desired.  When it is suppressed, the value of cribbing sent to the device will be zero.  The only exception to this would be if the order is for a digital lens style, and the device parameters, "Digital" tab has its "Send blank diameter as CRIB when CRIB=0 or is suppressed". 

Image Added

Cribbing can be suppressed several ways.  there are several checkboxes that control crib suppression,  they are contained in the "Lens Style" maintenance,  "Order" maintenance and "Device parameters" maintenance.   When one of these flags is checked, the crib sent to the device will be suppressed.

Image AddedImage AddedImage Added

Elliptical Cribbing (ELLH)

To use elliptical cribbing (this is the ELLH label in VCA terminology), there are several things that must be set up in Rx-Universe.

Setting system defaults

The system wide defaults for ELLH are located in the System Parameters program, under the “Devices” tab.

...

If both of the above limits are used, then the largest of the 2 values becomes the acceptable minimum.

Lens Style setting

ELLH can be suppressed by lens style, similar to cribbing.  One thing to remember is that if cribbing is suppressed, then the ELLH is automatically suppressed. 


Setting up the Device Parameters

The ELLH value on a job can be controlled by VCA device also.  The settings in the device parameters screen , under the  “Generator” tab, allow for more control on an individual device.

 


For each device you can set the following:

...

The crib and ELLH values can also be viewed in the “Devices fields” screen.

 

...