Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Note: This proprietary format for submitting electronic orders is provided for the use of laboratories licensed to use Rx-Universe only. It cannot be shared with outside companies or sources without prior, written consent from Optical Laboratory Software Solutions.

Overview:

The Remote Order Entry process allows a third-party program to create an ASCII file for Rx-Universe, containing information necessary to order an Rx from the lab.  This file uses the VCA convention for data transfers, with additional labels defined by Rx-Universe for fields not directly supported by the VCA device standard.  These additional labels will have a suffix of an underscore “_”; for example “_FIRSTNAME”.

Rx-Universe can also create a status file which the third-party software can retrieve to obtain the status of each of the site’s job in the lab.  The lab would need the Rx-Tracker module installed to accomplish this task. Figure I-1 shows this process. 

Rx-Universe can also add external information to an order by using a VCA file.  

This document will explain what codes you need to send to Rx-Universe, the format in which the request/orders will need to be sent to Rx-Universe and how to interpret the information that Rx-Universe sends back.


Figure 1-1

Rx-Universe Inbox (for incoming orders into the lab)

Information (RAW files) coming from the retail site will be stored in a folder determined by the lab which is located on the lab’s server.  The most common method of file transfer from a retail site to the lab is via ftp, where the default folder for the ftp transfer will point to the appropriate folder.  By default the folder is “OMICSTX” a subfolder of the “RXUNIVERSE” folder on the lab’s server.  For example “C:\RXUNIVERSE\OMICSTX”.


Rx-Universe

...

LMS Inbox (for

...

incoming optional order information)

Some devices require external information to be available. The remote processor program will look for files in a folder based on the "Directory for incoming orders" in the Remote Parameters settings.  For example “C:\RXUNIVERSE\OMICSTX\OMICSRX”LMS”.Under this folder there is a folder for each customer created by Rx-Universe automatically, the folder name will be the account number, this is where the retail site will have to pick up the status files. 

  • For example “C:\RXUNIVERSE\OMICSRX\account_number”:
    • “C:\RXUNIVERSE\OMICSRX\1” (status files for account 1)
    • “C:\RXUNIVERSE\OMICSRX\0025” (status files for account 0025)
    • “C:\RXUNIVERSE\OMICSRX\1234” (status files for account 1234)

Naming Conventions

There are naming conventions that are used for every document Rx-Universe either sends or receives and the directories they are stored in.  Each of these naming conventions will be explained as we get into detail about each document.

Sending Orders To Rx-Universe

File Name:

The naming convention that is used for the order file is very important.  The retailer will need to get their account number from the lab and store it somewhere in their system, since it is used in the flat file (RAW File) name.
The format of the file name is Account Number.V + sequence number (2 to 4 digits)

Example:

If the account number is “002” and this is the first order that they are sending, the text file name would be “002.V01” or “002.V0001”
The second file would be “002.V02” or “002.V0002” ... and so on.  Once the sequence number reaches its upper limit, the sequence number should restart from the beginning; for example, after “002.V9999” it should be “002.V0001”.

Steps in sending an Order to the lab:
       Generate ASCII text file (RAW File) for every order that has not been sent.
       Send the ASCII text file(s) (RAW File) to the lab.

File Format
Each line in the ASCII file must have at least two parameters, the first parameter being the field name (label), the second parameter the field value.  These parameters must be separated by an equal sign “=”.  Each field must go on a different line.  Field names with no underscore “_” at the beginning of its name are VCA Labels.  For more detail information on VCA Labels, reference the VCA Data Communication Standard documentation.

Some fields you have to send a right value and a left value, separated by a semi-colon.  These fields are indicated by the "chiral" column. Here is an example:

FIELDNAME=RightData;LeftData
                       SPH=-1.25;-0.75

If you are only sending Left eye information, you still have to include the semi-colon before the field value:

FIELDNAME=;LeftData
                       SPH=;-0.75

A complete order file will consists of many fields, with corresponding values.  A list of fields is given; following the list is an example of a complete order submission. 

General Information

Required column - O=optional, R=required
Chiral column - N=non-chiral (one value per label); Y=chiral (value is right, semi-colon, left - ie 2.50;1.25)

...

_CUSTNO

...

O

...

String

...

09

...

Account Number

...

JOB

...

R

...

String

...

21

...

Job number from retail

...

This information is saved in the “PO#” field.

...

_INV
or
ORDER-NUM

...

O

...

String

...

08

...

Invoice number

...

Use this field if you want to keep the same Invoice Number as
the sending/original system.

...

_OMICS_TRAY_NUM

...

O

...

String

...

06

...

Tray Number

Use this field if you want to keep the same Tray Number as
the sending/original system.

...

_JTYPE

...

R

...

String

...

01

...

Job Type

...

Valid Values:
“1” – Full Job
“2” – Uncut Job

...

PATIENT

...

R

...

String

...

21

...

Patient Name

...

This field is not needed if you are using the “_FIRSTNAME” and
“_LASTNAME” labels.

...

_FIRSTNAME

...

R

...

String

...

21

...

First name of patient

...

Use either PATIENT or combination of first and last name

...

_LASTNAME

...

R

...

String

...

21

...

Last name of patient

...

Use either PATIENT or combination of first and last name

...

_RDATE

...

O

...

String

...

08

...

Date Ordered

...

YYYYMMDD

...

_WDATE

...

O

...

String

...

08

...

Date Wanted

...

YYYYMMDD

...

_OPT_WDATE

...

O

...

String

...

8

...

Optional date wanted

...

YYYYMMDD

...

REF
or

_REF

...

O

...

String

...

18

...

Release Number

...

SHIPTO

...

O

...

String
String
String
String
String
String

...

10
35
25
25
20
24

...

Ship to Number
Ship to Name
Address Line 1
Address Line 2
Address Line 3
Address Line 4

...

Each part separated by a comma.

...

REM
or
_COMMENT

...

O

...

String

...

30

Remarks or Special Instructions.

...

Can have up to 11 comment lines.

...

_CALLFST

   

...

O

...

String

...

01

...

Call first before processing.
Set to Y will cause Rx-Universe to save the job unvalid and on hold. 
(ie. call dispenser before processing).

...

Valid Entries are:
“Y” – Yes
"N” or blank – No

...

_REMAKECODE

...

O

...

String

...

04

...

Remake code

...

An entry in this field sets the REDO flag on the order and
sets the job as Unvalid

...

_RUSH_JOB

...

O

...

String

...

01

...

Set Rush indicator on order

...

Valid Entries are:
“Y” – Yes
“N” or blank – No

...

_DOCTOR_ID

...

O

...

String

...

30

...

Doctor’s name

...

_ORD-ORIG_INVOICE

...

O

...

String

...

08

...

Used to send the original invoice number when sending a remake job

...

_REMAKE_CAT

...

O

...

String

...

04

...

Used to send the remake category

...

_PRLIST

...

O

...

String

...

03

...

Price list number.

...

Specify to force pricing to a certain lab price list.

...

_TRAY_COLOR

...

O

...

String

...

03

...

Used to override the tray color that would normally be associated
with the order.

...

_LAYOUT

...

O

...

String

...

01

...

Indicates whether frame measurements should be considered exact,
approximate, or not present.

...

Valid Entries are:
“A” – Approximate (do not use for finish layout calculation)
"E” – Exact measurements.
“U” – Uncut job, no frame measurements present,
         just uncut diameter.

...

_UNCUTDIAM

...

O

...

Numeric

...

05

...

Diameter to use for thickness for uncut job
(with no frame measurements)

...

Value >= 0 and <= 99.9
Ex: _UNCUTDIAM=65;67

...

_USER_DEF_JF

...

C

...

String

...

10

...

User Define Job Flow Labels.
Job Tracking module is required.

Rx And Lens Information

...

DO
or

_EYE

...

R

...

String

...

01

...

Which eye

...

Valid Values:
“R” = Right
“L” = Left
“B” = Both

...

_LSTYLE
See Appendix 2

...

C

...

String

...

06

...

If _LCODE not specified, this field specifies the lab code for the lens style being ordered

...

_MATERIAL
See Appendix 2

...

C

...

String

...

02

...

If _LCODE not specified, this field specifies the lab code for the lens material being ordered

...

_TREAT
See Appendix 2

...

C

...

String

...

03

...

If _LCODE not specified, this field specifies the lab code for the treatment of the lens
being ordered (if any)

...

This is the Pretreatment that comes already on the lens from the manufacturer.

...

_TINT
See Appendix 2

...

C

...

String

...

03

...

If _LCODE not specified, this field specifies the lab code for the tint of the lens
being ordered (if any)

...

This is the Tint (Color) that comes already on the lens from the manufacturer

...

_LCODE
See Appendix 1

...

C

...

String
String
String
String

...

02
06
03
03

...

Lens Material
Lens Style
Lens Treatment
Lens Tint
Required if you are ordering lenses.

...

Refer to catalogue reference, under the lens section.  This is the code from the catalogue
which specifies the lens product to order.
NOTE: you may use _LSTYLE, _MATERIAL, _TINT and _TREAT in lieu of the _LCODE
In our experience, it is easier to use the other labels than using _LCODE.

...

SPH +/-

...

R

...

Numeric

...

05

...

Rx Sphere Power

...

Range from -39.0 to +49.0 and must be a multiple of 0.125, rounded to 2
decimal places (ie. 0.12, 0.25, 0.37, etc.), unless the lab supports powers in 1/100 D

...

CYL  +/-

...

O

...

Numeric

...

05

...

Rx Cylinder Power

...

Valid values range from-19.75 to +19.75, in increments of 0.125, rounded to
the nearest 2 decimal places, unless the lab supports powers in 1/100 D

...

AX

...

C

...

Integer

...

03

...

Prescribed Cylinder Axis.
This field is required if the “CYL” field is specified for the eye.

...

Valid values range from 0 to 180. 

...

IPD

...

R

...

Numeric

...

03

Far PD: The far interpupillary distance for Multifocals and can be entered as
monocular or binocular PD.
or
This can also be the Horizontal Decentration.

...

Valid range values:
For monocular: 17mm to 38mm. 
For Ex: IPD=30.0;30.5
For binocular: 39mm and over. 
For Ex: IPD=60.0;61.0
16 or less indicates decentration.  This value may be negative, indicating “out” decentration.

...

NPD

...

C

...

Numeric

...

03

Near PD or Vertical Decentration:
This is the near interpupillary distance for Multifocals and can be entered as
monocular or binocular PD.
or
This can also be the Vertical Decentration for Single Vision lenses.

...

Valid range values:
For monocular: 17mm to 38mm. 
For Ex: IPD=30.0;30.5
For binocular: 39mm and over. 
For Ex: IPD=60.0;61.0

For SV-Style lenses, this field represents the distance above or below the datum of the OC. 
If the value is positive, it’s above the datum and if the value is negative, it’s below the datum.

...

OCHT

...

O

...

Numeric

...

04

...

Vertical O.C. height measured from the lower boxes tangent of the frame.

...

ADD

...

C

...

Numeric

...

04

...

The add power of the multifocal segment; required for multifocal lenses

...

99.99

...

ADD2

...

C

...

Numeric

...

04

...

The add power of the upper segment in an occupational lens

...

99.99

...

SEGHT
or
SGHT

...

C

...

Numeric

...

03

...

Segment Height
Required for multifocal lenses – this is the height of the segment from the bottom of the frame.
Valid range of values is from +10.0mm to +40.0mm, in increments of 0.5mm.

...

Ex: SEGHT=19;19

...

PRVM  +/-

...

O

...

Numeric

...

04

...

Rx Prism in diopters
Can specify up to 2 Rx Prisms per eye.

...

Ex:
PRVM=1.50;3.00
PRVM=0.50;0.75

...

PRVA

...

C

...

String

...

03

...

Rx Prism direction
Required if PRVM has been populated
Prism direction is the axis of the prism base, from 1 to 360 degrees
You are allowed to specify as many PRVAs as PRVMs

...

Ex:
PRVA=090;090
PRVA=000;180

...

ELLH

...

O

...

Numeric

...

02

...

Elliptical Cribbing

...

Ex: ELLH=62;62

...

_SUPELLH

...

O

...

String

...

01

...

Suppress Elliptical Cribbing
Suppress means do not do Elliptical Cribbing

...

Valid Values are:
“Y” – Do suppress
"N” or blank – Do not suppress

...

THNP

...

O

...

Numeric

...

03

...

Requested edge thickness at the thinnest edge
If job has frame measurements, this is the thickness at the thinnest edge point on the frame.
If uncut without frame, this is the thickness at the thinnest edge point on the crib shape.

...

Ex: THNP=1.5;1.5

...

_PRTHIN

...

O

...

String

...

01

...

Prism Thinning
If you activate this option, OMICS will use the Prism Thinning value assigned to this account.

...

Valid Entries Are:
“Y” – Yes, perform Prism Thinning
“N” – No, Do Not, perform Prism Thinning

...

_ADDON

...

O

...

String

...

06

...

Add-on Codes
Can have up to 15 add-ons

...

Codes specified by receiving lab or from catalogue.

...

CLASS

...

O

...

String

String

...

03

03

...

To force Finished (Stock) or Semi-Finish lenses per eye
CLASS=FIN;SFN

...

Valid Values
“FIN”  = Finished Job
“SFN” = Semi-Finished Job
This works the same way as _FORCESF_F

...

_FORCESF_F

...

O

...

String

...

01

...

To force Semi-Finish or Finished (Stock) lenses on your job

...

Valid Values:
“2” = force finished lenses
“3” = force semi-fin lenses
This works the same way as “CLASS”.

...

_RFRONT
or
MBASE

...

O

...

String

...

04

...

Requested Nominal Front Curve

...

Ex: _RFRONT=0400;0400
or
MBASE=0400;0400

...

_RDIA

...

O

...

Numeric

...

02

...

Requested Blank (Lens) Diameter

...

Ex: _RDIA=76;76

...

_LMFRID
or
LMFR

...

O

...

String

...

04

...

Lens Manufacturer

...

If you want to force Rx-Universe to select a lens from a certain manufacturer

...

OPC

...

O

...

Numeric

...

10

...

Lens OPC Code

...

Select lenses by OPC codes

...

SWIDTH

...

C

...

Numeric

...

02

...

Segment Width
Required only for certain Bifocal lenses.
This is not needed when the Lens Style selected already specify the Segment Width.

...

Ex:_SWIDTH=28;28

...

SDEPTH

...

C

...

Numeric

...

02

...

Segment Depth of the Intermediate Segment.  Required only for Trifocal lenses
This is not needed when the Lens Style selected already specify the Segment Depth

...

Ex:SDEPTH=08;08

...

LNAM

...

O

...

String

...

23

...

VCA Label Translation

...

LTYP

...

O

...

String

...

23

...

VCA Label Translation

...

LMATTYPE

...

O

...

String

...

23

...

VCA Label Translation

...

HBOX

...

C

...

Numeric

...

03

...

Horizontal box lens size of the frame.  This is the “A” measurement
This field is required if there is no pattern sent

...

Valid range of values is from 30.0 to 80.0 mm

...

VBOX

...

C

...

Numeric

...

03

...

Vertical boxes lens size of the frame.  This is the “B” measurement.
This field is required if there is no pattern sent or if the HBOX measurement exists.

...

Valid range of values is from 15.0 to 60.0 mm

...

_EDBOX

...

C

...

Numeric

...

03

...

“ED” measurement of the box measurement system.  The widest possible
diameter of the Frame
This field is required if there was no pattern sent and the brow, cheek,
and temple are not supplied.

...

Valid range of values is from 30.0 to 80.0 mm

...

DBL

...

R

...

Numeric

...

03

...

Distance Between Lenses

...

Valid range of values is from 7.0 to 30.0 mm

...

ETYP

...

O

...

String

...

01

...

Type of edge to cut on lens.

...

Valid Entries are:
1 – Bevel
2 – Rimless (drilllmount)
3 – Groove

...

SFTHK

...

O

...

String

...

01

...

This field needs to be placed after the “ETYP” field

...

Y = Safety Thickness

...

FTYP

...

O

...

String

...

01

...

Frame Type

...

Valid Entries are:
1 – Zyl (Z)
2 – Metal (M)
3 – Rimless 

...

_TRACE
See Appendix 3

...

O

...

String

...

12

...

Trace Number

...

Rx-Universe will look into the Pattern Database for a Frame Name matching
the value of “_TRACE”, with the Manufacturer of “DATA”, the Nominal A Size
field being blank and the Nominal Bridge field being blank.

...

_CCIRC
or
CIRC

...

O

...

Numeric

...

04

...

You can specify the actual circumference of the customer’s frame.
This will only work if a trace has been attached to the job by sending the frame trace data
or by selecting a pattern or frame with tracing information from the Rx-Universe Tracing
Database.  For example, with the use of _TRACE label.

Ex: CIRC=138.4

...

_WRAP

...

O

...

String

...

01

...

To take advantage of the Wrap Frame Calculation.
Required: FrameWorks V2.0 (or higher) to be installed on the processing computer. 
If the processing computer is connected to the server through thin client, then it has
to be installed on the server.

...

Valid Entries are:
“Y” – Yes
“N” or blank – No

...

ZTILT

...

O

...

Numeric

...

03

...

Panoramic (Wrap) Angle
Required:
_WRAP to be valid

...

Valid range of values is from 0 to 30.0 degrees

...

PANTO

...

O

...

Numeric

...

03

...

Pantoscopic (Angle) Tilt
Required:

_WRAP to be valid.

...

Valid range of values is from 0 to 30.0 degrees

...

BVD
or
_VERT_FITTING

...

O

...

Numeric

...

03

...

Vertex Fitting.  Back vertex distance, as worn (mm)
Required:
_WRAP to be valid

...

Valid range of values is from 5 to 30 mm

...

RVD

...

O

...

Numeric

...

03

...

Refracted Vertex Distance - Back vertex distance, as refracted (mm)
Required:
_WRAP to be valid

...

Valid range of values is from 5 to 30 mm

 

...

TRCFMT

...

O

...

Numeric

...

01

...

Format of frame trace data
For more detail information, reference the VCA Data Communication
Standard documentation.

...

Valid Entries are:
0 – No Trace sent.
1, 3, 4 – supported by Rx-Universe and specified in VCA standard
2 – NOT supported by Rx-Universe
5..100 – are reserved for future standards.

...

Number

...

04

...

Number of radii in the trace

...

String

...

01

...

Radius mode identifier

...

Valid Entries are:
“E” – the radii are evenly spaced
“U” – the radii are unevenly spaced

...

String

...

01

...

Which eyes are included

...

Valid Entries are:
“R” – Right
“L” – Left
“B” – Both

...

ZFMT

...

O

...

Numeric

...

01

...

Format of vertical height frame trace data
For more detail information, reference the VCA Data Communication
Standard documentation.

...

Valid Entries are:
0 – No Trace sent
1, 3, 4 – supported by Rx-Universe and specified in VCA standard
2 – NOT supported by Rx-Universe
5..100 – are reserved for future standards

...

Number

...

04

...

Number of radii in the trace

...

String

...

01

...

Radius mode identifier

...

E – the radii are evenly spaced
U – the radii are unevenly spaced

...

String

...

01

...

Which eyes are included

...

R – Right
L – Left
B – Both

...

R

...

C

...

Numeric

...

05

...

Radius Data
For more detail information, reference the VCA Data Communication
Standard documentation.

...

Separate values for this field by a semi-colon “;” such as:
R=2479;2583;2605;2527;…
All of the records follow the 80-character line limit rule; therefore there may (in fact, will likely)
be multiple R records for each tracing.  Radius is expressed in hundredths of a degree with an
implied decimal point.

A

...

C

...

Numeric

...

05

...

Angle data for radius data (angular locations of trace radii expressed
in R record(s))
For more detail information, reference the VCA Data Communication
Standard documentation.

...

Separate values for this field by a semi-colon “;” such as:
A=010;015;020;025;…

...

Z

...

C

...

Numeric

...

05

...

Radius Data
For more detail information, reference the VCA Data Communication
Standard documentation.

...

Separate values for this field by a semi-colon “;” such as:
Z=179;183;205;227;…
All of the records follow the 80-character line limit rule; therefore there may (in fact, will likely) be
multiple Z records for each tracing.  Height is expressed in hundredths of a degree with an implied
decimal point.

...

Center thickness - used only if a specific center thickness is desired for the lens.  This can
be specified for both minus power and plus power lenses.

...

The files placed in this folder must be names as follows, "order#.LMS".   The information in these files will be stored on the specified order in the VCA overrides data.  

An example of file contents would be:

ANS=LMS

STATUS=0;

JOB=13000423

LDDRSPH=5.00;5.30

LDDRCYL=-0.52;-0.50

LDDRAX=90;71

LDDADD=2.43;2.40

LDDPRVM=1.25;1.25

LDDPRVA=270;270


When the Remote processor has reviewed the file, it will be moved to a subfolder called "PROCESSED", if there was an error with the file, it will be placed in a subfolder called "ERRORS".  The number of LMS files processed and the number of errors encountered can be seen on the main Remote processor window.

Image Added

If you need to troubleshoot the files in the "ERRORS" folder, you can turn on the "HOYA LMS log" in the "Remote Parameters" settings screen, then move the files from the "ERRORS" folder to the "LMS" folder for reprocessing.  A log file called "HOYALMS.LOG" will be created in the RxUniverse folder.  Remember to turn the log fill off when you are done troubleshooting. 

Rx-Universe Outbox (for outgoing status results)

Information that is sent back from Rx-Universe will be located in this directory, which is usually called “OMICSRX” – this is usually a subfolder below the default “RXUNIVERSE” folder on the lab’s server.  For example “C:\RXUNIVERSE\OMICSRX”.  Under this folder there is a folder for each customer created by Rx-Universe automatically, the folder name will be the account number, this is where the retail site will have to pick up the status files. 

  • For example “C:\RXUNIVERSE\OMICSRX\account_number”:
    • “C:\RXUNIVERSE\OMICSRX\1” (status files for account 1)
    • “C:\RXUNIVERSE\OMICSRX\0025” (status files for account 0025)
    • “C:\RXUNIVERSE\OMICSRX\1234” (status files for account 1234)

Naming Conventions

There are naming conventions that are used for every document Rx-Universe either sends or receives and the directories they are stored in.  Each of these naming conventions will be explained as we get into detail about each document.

Sending Orders To Rx-Universe

File Name:

The naming convention that is used for the order file is very important.  The retailer will need to get their account number from the lab and store it somewhere in their system, since it is used in the flat file (RAW File) name.
The format of the file name is Account Number.V + sequence number (2 to 4 digits)

Example:

If the account number is “002” and this is the first order that they are sending, the text file name would be “002.V01” or “002.V0001”
The second file would be “002.V02” or “002.V0002” ... and so on.  Once the sequence number reaches its upper limit, the sequence number should restart from the beginning; for example, after “002.V9999” it should be “002.V0001”.

Steps in sending an Order to the lab:
       Generate ASCII text file (RAW File) for every order that has not been sent.
       Send the ASCII text file(s) (RAW File) to the lab.


File Format
Each line in the ASCII file must have at least two parameters, the first parameter being the field name (label), the second parameter the field value.  These parameters must be separated by an equal sign “=”.  Each field must go on a different line.  Field names with no underscore “_” at the beginning of its name are VCA Labels.  For more detail information on VCA Labels, reference the VCA Data Communication Standard documentation.

Some fields you have to send a right value and a left value, separated by a semi-colon.  These fields are indicated by the "chiral" column. Here is an example:

FIELDNAME=RightData;LeftData
                       SPH=-1.25;-0.75

If you are only sending Left eye information, you still have to include the semi-colon before the field value:

FIELDNAME=;LeftData
                       SPH=;-0.75

A complete order file will consists of many fields, with corresponding values.  A list of fields is given; following the list is an example of a complete order submission. 

General Information

Required column - O=optional, R=required, C=conditional (dependent on other tags)
Chiral column - N=non-chiral (one value per label); Y=chiral (value is right, semi-colon, left - ie 2.50;1.25)

Field NameReqdChiralData TypeLengthDescriptionFormat / Valid Values

_CUSTNO

O

N

String

09

Account Number


JOB

R

N

String

20

Job number from retail

This information is saved in the “PO#” field.

_INV
or
ORDER-NUM

O

N

String

08

Invoice number

Use this field if you want to keep the same Invoice Number as
the sending/original system.

_OMICS_TRAY_NUM

O

N

String

06

Tray Number

Use this field if you want to keep the same Tray Number as
the sending/original system.


_JTYPE

R

N

String

01

Job Type

Valid Values:
“1” – Full Job
“2” – Uncut Job
“5” – Addon Job
“6” – Edge-only Job

PATIENT

C

N

String

21

Patient Name

This field is not needed if you are using the “_FIRSTNAME” and
“_LASTNAME” labels.

_FIRSTNAME

C

N

String

21

First name of patient

Use either PATIENT or combination of first and last name

_LASTNAME

C

N

String

21

Last name of patient

Use either PATIENT or combination of first and last name

_RDATE

O

N

String

08

Date Ordered

YYYYMMDD

_WDATE

O

N

String

08

Date Wanted

YYYYMMDD

_OPT_WDATE

O

N

String

8

Optional date wanted

YYYYMMDD

REF
or

_REF

O

N

String

18

Release Number


SHIPTO

O

N

String
String
String
String
String
String
String

10
35
25
25
20
24
10

Ship to Number
Ship to Name
Address Line 1
Address Line 2
Address Line 3
Address Line 4
Zip or postal code

Each part separated by a comma.


_SHIPMETHOD or
_SHIPMETH
ONString04Shipping Method Code

REM
or
_COMMENT

O

N

String

30

Remarks or Special Instructions.


Can have up to 11 comment lines.

_CALLFST

   

O

N

String

01

Call first before processing.
Set to Y will cause Rx-Universe to save the job unvalid. 
(ie. call dispenser before processing).

Valid Entries are:
“Y” – Yes
"N” or blank – No

_REMAKECODE

O

N

String

04

Remake code

An entry in this field sets the REDO flag on the order and
sets the job as Unvalid

_RUSH_JOB

O

N

String

01

Set Rush indicator on order

Valid Entries are:
“Y” – Yes
“N” or blank – No

_DOCTOR_ID

O

N

String

30

Doctor’s name


_ORD_ORIG_INVOICE

O

N

String

08

Used to send the original invoice number when sending a remake job


_REMAKE_CAT

O

N

String

04

Used to send the remake category


_PRLIST

O

N

String

03

Price list number.

Specify to force pricing to a certain lab price list.

_TRAY_COLOR

O

N

String

03

Used to override the tray color that would normally be associated
with the order.


_LAYOUT

O

N

String

01

Indicates whether frame measurements should be considered exact,
approximate, or not present.

Valid Entries are:
“A” – Approximate (do not use for finish layout calculation)
"E” – Exact measurements.
“U” – Uncut job, no frame measurements present,
         just uncut diameter.

_UNCUTDIAM

O

Y

Numeric

05

Diameter to use for thickness for uncut job
(with no frame measurements)

Value >= 0 and <= 99.9
Ex: _UNCUTDIAM=65;67

_USER_DEF_JF

C

N

String

10

User Define Job Flow Labels.
Job Tracking module is required.


_FSTATUSONString01Frame status for the order

Valid Entries are: 

"1" or "S"- Supply frame

"2" or "F" - Frame to follow

"3" or "O" - Other

"4" or "E" - Frame enclosed

"5" or "L" - Lenses only

"6" OR "N" - Supply frame at no charge

_ROUTEONString04Work ticket routing for work ticketLPT1, LPT2, up to LPT9
If used, this directs the work ticket to be printed to the specified
printer routing.  If left blank, normal routing rules will be used 
when the order is processed.

_BALANCE

ONString01Indicates one eye is a balance lensValid entries are R, L or blank
_BALANCE=R
(introduced in version 7.52)
_HOLDORDERONString01Makes the order processor place an order on hold

Valid entries are Y N or blank

_REMOTE_USER_NAMEONString20Name of the user entering the remote orderIntroduced in version 7.73


Rx And Lens Information

Field NameReqdChiralData TypeLengthDescriptionFormat / Valid Values

DO
or

_EYE

R

Y

String

01

Which eye

Valid Values:
“R” = Right
“L” = Left
“B” = Both

_LSTYLE
See Appendix 2

C

Y

String

06

If _LCODE and UPC are not specified, this field specifies the lab code for the lens style being ordered


_MATERIAL
See Appendix 2

C

Y

String

02

If _LCODE and UPC are not specified, this field specifies the lab code for the lens material being ordered


_TREAT
See Appendix 2

C

Y

String

03

If _LCODE and UPC are not specified, this field specifies the lab code for the treatment of the lens
being ordered (if any)

This is the Pretreatment that comes already on the lens from the manufacturer.

_TINT
See Appendix 2

C

Y

String

03

If _LCODE and UPC are not specified, this field specifies the lab code for the tint of the lens
being ordered (if any)

This is the Tint (Color) that comes already on the lens from the manufacturer

_LCODE
See Appendix 1

C

Y

String
String
String
String

02
06
03
03

Lens Material
Lens Style
Lens Treatment
Lens Tint
Required if you are ordering lenses.

Refer to catalogue reference, under the lens section.  This is the code from the catalogue
which specifies the lens product to order.
NOTE: you may use _LSTYLE, _MATERIAL, _TINT and _TREAT in lieu of the _LCODE
In our experience, it is easier to use the other labels than using _LCODE. 

You may also use UPC with the UPC translation table to specify materials, lens styles,
tints and treatments, as well as addons.

SPH +/-

R

Y

Numeric

05

Rx Sphere Power

Range from -39.0 to +49.0 and must be a multiple of 0.125, rounded to 2
decimal places (ie. 0.12, 0.25, 0.37, etc.), unless the lab supports powers in 1/100 D

CYL  +/-

O

Y

Numeric

05

Rx Cylinder Power

Valid values range from-19.75 to +19.75, in increments of 0.125, rounded to
the nearest 2 decimal places, unless the lab supports powers in 1/100 D

AX

C

Y

Integer

03

Prescribed Cylinder Axis.
This field is required if the “CYL” field is specified for the eye.

Valid values range from 0 to 180. 

IPD

R

Y

Numeric

03

Far PD: The far interpupillary distance for Multifocals and can be entered as
monocular or binocular PD.
or
This can also be the Horizontal Decentration.


Valid range values:
For monocular: 17mm to 38mm. 
For Ex: IPD=30.0;30.5
For binocular: 39mm and over. 
For Ex: IPD=60.0;61.0
16 or less indicates decentration.  This value may be negative, indicating “out” decentration.

NPD

C

Y

Numeric

03

Near PD or Vertical Decentration:
This is the near interpupillary distance for Multifocals and can be entered as
monocular or binocular PD.
or
This can also be the Vertical Decentration for Single Vision lenses.



Valid range values:
For monocular: 17mm to 38mm. 
For Ex: IPD=30.0;30.5
For binocular: 39mm and over. 
For Ex: IPD=60.0;61.0

For SV-Style lenses, this field represents the distance above or below the datum of the OC. 
If the value is positive, it’s above the datum and if the value is negative, it’s below the datum.

OCHT

O

Y

Numeric

04

Vertical O.C. height measured from the lower boxes tangent of the frame.


ADD

C

Y

Numeric

04

The add power of the multifocal segment; required for multifocal lenses

99.99

ADD2

C

Y

Numeric

04

The add power of the upper segment in an occupational lens

99.99

SEGHT
or
SGHT

C

Y

Numeric

03

Segment Height
Required for multifocal lenses – this is the height of the segment from the bottom of the frame.
Valid range of values is from +10.0mm to +40.0mm, in increments of 0.5mm.

Ex: SEGHT=19;19

SEGDHTOYNumeric04

The field contains the length in millimeters from the top of the segment or fitting cross (if progressive type lens) or the vertical decentration point of a single vision lens,  to the point where the vertical line would cross the frame.  The position of the line would be vertically from the distance power location (see diagram). 

Image Added  

When the SEGDHT is supplied, the value is used along with a trace pattern, to calculate the value of SEGHT of a multi-focal lens or the vertical decentration of a single vision lens.. 

Ex:

SEGDHT=10.2;10.2

PRVM  +/-

O

Y

Numeric

04

Rx Prism in diopters
Can specify up to 2 Rx Prisms per eye.

Ex:
PRVM=1.50;3.00
PRVM=0.50;0.75

PRVA

C

Y

String

03

Rx Prism direction
Required if PRVM has been populated
Prism direction is the axis of the prism base, from 1 to 360 degrees
You are allowed to specify as many PRVAs as PRVMs

Ex:
PRVA=090;090
PRVA=000;180

ELLH

O

Y

Numeric

02

Elliptical Cribbing

Ex: ELLH=62;62

_SUPELLH

O

Y

String

01

Suppress Elliptical Cribbing
Suppress means do not do Elliptical Cribbing

Valid Values are:
“Y” – Do suppress
"N” or blank – Do not suppress

THNP

O

Y

Numeric

03

Requested edge thickness at the thinnest edge
If job has frame measurements, this is the thickness at the thinnest edge point on the frame.
If uncut without frame, this is the thickness at the thinnest edge point on the crib shape.

Ex: THNP=1.5;1.5

_PRTHIN

O

N

String

01

Prism Thinning
If you activate this option, OMICS will use the Prism Thinning value assigned to this account.

Valid Entries Are:
“Y” – Yes, perform Prism Thinning
“N” – No, Do Not, perform Prism Thinning

_ADDON

O

N

String

06

Add-on Codes
Can have up to 15 add-ons

Codes specified by receiving lab or from catalogue.

As of version 7.59.02, _ADDON can also be specified as:
_ADDON=code;description
where "code" is an addon code (as previous), and "description" is a description or comment of the addon that will be populated into the addon remarks on the order entry screen, Addon tab.  

CLASS

O

Y

String

String

03

03

To force Finished (Stock) or Semi-Finish lenses per eye
CLASS=FIN;SFN

Valid Values
“FIN”  = Finished Job
“SFN” = Semi-Finished Job
This works the same way as _FORCESF_F

_FORCESF_F

O

Y

String

01

To force Semi-Finish or Finished (Stock) lenses on your job

Valid Values:
“2” = force finished lenses
“3” = force semi-fin lenses
This works the same way as “CLASS”.

_RFRONT
or
MBASE

O

Y

String

04

Requested Nominal Front Curve

Ex: _RFRONT=0400;0400
or
MBASE=0400;0400

_RDIA

O

Y

Numeric

02

Requested Blank (Lens) Diameter

Ex: _RDIA=76;76

_LMFRID
or
LMFR

O

Y

String

04

Lens Manufacturer

If you want to force Rx-Universe to select a lens from a certain manufacturer

OPC

O

Y

Numeric

10

Lens OPC Code

Select lenses by OPC codes

SWIDTH

C

Y

Numeric

02

Segment Width
Required only for certain Bifocal lenses.
This is not needed when the Lens Style selected already specify the Segment Width.

Ex:_SWIDTH=28;28

SDEPTH

C

Y

Numeric

02

Segment Depth of the Intermediate Segment.  Required only for Trifocal lenses
This is not needed when the Lens Style selected already specify the Segment Depth

Ex:SDEPTH=08;08

LNAM

O

Y

String

23

VCA Label Translation


LTYP

O

Y

String

23

VCA Label Translation









HBOX

C

O

Numeric

03

Horizontal box lens size of the frame.  This is the “A” measurement
This field is required if there is no trace sent

Valid range of values is from 30.0 to 80.0 mm

VBOX

C

O

Numeric

03

Vertical boxes lens size of the frame.  This is the “B” measurement.
This field is required if there is no trace sent or if the HBOX measurement exists.

Valid range of values is from 15.0 to 60.0 mm

_EDBOX

C

O

Numeric

03

“ED” measurement of the box measurement system.  The widest possible
diameter of the Frame
This field is required if there was no trace sent and the brow, cheek,
and temple are not supplied.

Valid range of values is from 30.0 to 80.0 mm

FEDCNNumeric03FED or ED measurement of the frame - same as _EDBOXValid range is from 30.0 to 80.0 mm

DBL

C

N

Numeric

03

Distance Between Lenses
This field is required if there was no trace sent and if the order if not an uncut without frame.

Valid range of values is from 7.0 to 30.0 mm

ETYP

O

N

String

01

Type of edge to cut on lens.

Valid Entries are:
1 – Bevel
2 – Rimless (drilllmount)
3 – Groove

SFTHK

O

N

String

01

This field needs to be placed after the “ETYP” field

Y = Safety Thickness

FTYP

O

N

Numeric

01

Frame Type

Valid Entries are:
1 – Zyl (Z)
2 – Metal (M)
3 – Rimless 

_SHAPEONString
Stored trace in RxUniverse that are saved as shapes (SHAP) names

Rx-Universe will look into the Trace Database for a Frame Name matching the value of “_SHAPE”, with the Manufacturer of “SHAP”. 

The VBOX and HBOX fields are checked against the stored shape's values and the _SHAPE trace will be resized accordingly and an INV# trace will be created using the order number as the trace name with the resized trace information and this will be attached to the received order.

If no VBOX or HBOX values were supplied in the remote order file, then the _SHAPE name is stored as the trace information name on the order with no adjustments made to the trace.

Note the _SHAPE traces are for calculations only and cannot be used on an edging machine.

_TRACE
See Appendix 3

O

N

String

12

Trace Number

Rx-Universe will look into the Pattern Database for a Frame Name matching the value of “_TRACE”, with a Manufacturer of “DATA”, the Nominal A Size field being blank and the Nominal Bridge field being blank.

The VBOX and HBOX fields are checked against the stored trace's values and the _TRACE data points will be resized accordingly and an INV# trace will be created using the order number as the trace name and the resized trace information, this INV# trace will be attached to the received order.

If no VBOX or HBOX values were supplied in the remote order file, then the _TRACE name is stored as the trace information name on the order with no adjustments made to the trace.

_CCIRC
or
CIRC

O

N

Numeric

04

You can specify the actual circumference of the customer’s frame.
This will only work if a trace has been attached to the job by sending the frame trace data
or by selecting a pattern or frame with tracing information from the Rx-Universe Tracing
Database.  For example, with the use of _TRACE label.

Ex: CIRC=138.4


_SLAB   ONString01Slab-Off

Valid Entries are:

"Y" - Yes

"N", "?", spaces or ":" - No

"R" - Reverse

_WRAP

O

N

String

01

To take advantage of the Wrap Frame Calculation.
Required: FrameWorks V2.0 (or higher) to be installed on the processing computer. 
If the processing computer is connected to the server through thin client, then it has
to be installed on the server.

Valid Entries are:
“Y” – Yes
“N” or blank – No

ZTILT

O

N

Numeric

03

Panoramic (Wrap) Angle
Required:
_WRAP to be valid

Valid range of values is from 0 to 30.0 degrees

PANTO

O

N

Numeric

03

Pantoscopic (Angle) Tilt
Required:

_WRAP to be valid.

Valid range of values is from 0 to 30.0 degrees

BVD
or
_VERT_FITTING

O

N

Numeric

03

Vertex Fitting.  Back vertex distance, as worn (mm)
Required:
_WRAP to be valid

Valid range of values is from 5 to 30 mm

RVD

O

N

Numeric

03

Refracted Vertex Distance - Back vertex distance, as refracted (mm)
Required:
_WRAP to be valid

Valid range of values is from 5 to 30 mm

 

TRCFMT

O

N

Numeric

01

Format of frame trace data
For more detail information, reference the VCA Data Communication
Standard documentation.

Valid Entries are:
0 – No Trace sent.
1, 3, 4 – supported by Rx-Universe and specified in VCA standard
2 – NOT supported by Rx-Universe
5..100 – are reserved for future standards.




Number

04

Number of radii in the trace





String

01

Radius mode identifier

Valid Entries are:
“E” – the radii are evenly spaced
“U” – the radii are unevenly spaced




String

01

Which eyes are included

Valid Entries are:
“R” – Right
“L” – Left
“B” – Both

ZFMT

O

N

Numeric

01

Format of vertical height frame trace data
For more detail information, reference the VCA Data Communication
Standard documentation.

Valid Entries are:
0 – No Trace sent
1, 3, 4 – supported by Rx-Universe and specified in VCA standard
2 – NOT supported by Rx-Universe
5..100 – are reserved for future standards




Number

04

Number of radii in the trace





String

01

Radius mode identifier

E – the radii are evenly spaced
U – the radii are unevenly spaced




String

01

Which eyes are included

R – Right
L – Left
B – Both

R

C

N

Numeric

05

Radius Data
For more detail information, reference the VCA Data Communication
Standard documentation.

Separate values for this field by a semi-colon “;” such as:
R=2479;2583;2605;2527;…
All of the records follow the 80-character line limit rule; therefore there may (in fact, will likely)
be multiple R records for each tracing.  Radius is expressed in hundredths of a degree with an
implied decimal point.

A



C

N

Numeric

05

Angle data for radius data (angular locations of trace radii expressed
in R record(s))
For more detail information, reference the VCA Data Communication
Standard documentation.

Separate values for this field by a semi-colon “;” such as:
A=010;015;020;025;…

Z

C

N

Numeric

05

Radius Data
For more detail information, reference the VCA Data Communication
Standard documentation.

Separate values for this field by a semi-colon “;” such as:
Z=179;183;205;227;…
All of the records follow the 80-character line limit rule; therefore there may (in fact, will likely) be
multiple Z records for each tracing.  Height is expressed in hundredths of a degree with an implied
decimal point.

CTHICK   OYNumeric05

Center thickness - used only if a specific center thickness is desired for the lens.  This can
be specified for both minus power and plus power lenses.

CTHICK=2.3;2.3
UPCOYNumeric12This is a translation code that can be used with the UPC translation file to specify either lens style, material, tint and treatment, or an addon code.  This allows a third party system to send one code that can be translated on the Rx-Universe side into the lab's codes for the lens product.

Frame and Miscellaneous Inventory Items 

If the lab uses the Rx-Universe Frame Inventory module, then frames, fronts, temples, bridges, side shields and miscellaneous items can be specified in the remote order. (added in version 7.35.00 of Rx-Universe)

Field NameReqdChiralData TypeLengthDescriptionFormat / Valid Values

_FRMID

O

N

String

80

This field can be used to specify the frame (or front or bridge) in three ways:

  1. _FRMID can be the 12 digit UPC (instead of using FUPC)
  2. _FRMID can be NAME, COLOR, MANUF, EYE, BRIDGE, TEMPLE, PART CODE separated by commas
  3. _FRMID can be the same fields, without commas, with the following fixed-length structure (this format is supported solely for compatibility with existing systems that export to OMICS in this format):
    NAME - 20 chars
    COLOR - 20 chars
    MANUF - 20 chars
    EYE - 2 digits
    BRIDGE - 2 digits
    TEMPLE - 3 digits
    PART CODE - one character, must be one of:   
         blank - full frame
         F - front
         B - bridge
         T - temple
         S - side shields

Required if "S"upply frame, and lab is using the frame inventory module.

Examples:

  1. _FRMID=123456789012
  2. _FRMID=SIMPLE,SILVER,ACME,52,18,135
  3. _FRMID=SIMPLE              SILVER              ACME                5218135
_FRPIDONString12Internal ID number or UPC of a temple (only valid if first field referred to a frame front)
A temple can also be specified using the same formats as #2 and #3 for _FRMID
Required if "S"upply frame, and the frame was just a front piece
_FRSIDONString12Internal ID number or UPC of a side-shield
A side shield can also be specified using the same formats as #2 and #3 for _FRMID
Required if "S"upply frame, and the frame was just a front piece.  It is optional if the frame was a full frame
_FSTATUSONString01

Valid Entries are: 

"1" or "S"- Supply frame

"2" or "F" - Frame to follow

"3" or "O" - Other

"4" or "E" - Frame enclosed

"5" or "L" - Lenses only

"6" OR "N" - Supply frame at no charge

FUPCONNumeric12This is the UPC number corresponding to the frame; it can be up to 12 numeric digitsex.  FUPC=112233445566
_MISCONString50

This is an identifier for a miscellaneous item, such as a frame case, cleaning cloth, etc.
It can be one of two formats:

  1. _MISC=upc - specifies the UPC of the item
  2. _MISC=NAME,MANUFACTURER

In the second format, the name and manufacturer should be separated by commas, and both values must match exactly with how the item is stored in Rx-Universe frame inventory.

ex.  _MISC=123456789012

_MISC=RED CASE,SAFILO

Optional Fields

Optional fields are parameters that are not required for all Rx's, but might be required for specific lens designs.  For example, the Varilux S 4D lens style requires head-eye coefficient to be specified by the dispenser.

...

Field NameReqdChiralData TypeLengthDescriptionFormat / Valid Values

CLINIT


N

String


Wearer’s Initials

up to 4 alphanumeric characters

CLHT


N

Numeric


Client Height in meters


HEADK


N

Numeric


Head Eye Coefficient

Measured by Visi-Office
Values 0 to 0.99

HEADS


N

Numeric


Stability Coefficient

Measured by Visi-Office
Valid values 0 to 0.15

_NVI


Y

Numeric


Near Vision Inset

Inset of the near vision segment relative
to the distance reference point
Valid values are 0 to 7.0 mm

NWD


N

Numeric


Near Working Distance

Working object distance at near viewing
point (in meters).

ERCD


Y

Numeric


Eye Rotation Center Distance

Measured by Visi-Office
Values 16.0 to 38.0 mm

CAPE


Y

Numeric

Cape Head Angle

Measured by Visi-Office
Values -10 to +10

_LP

Y

Progression Length (corridor length)

Valid values vary by design
Typically 13, 14, 15, etc., in 1/10 increments

DMNTEYE

N

Dominant Eye

R-right, L-left, or N-none

_CLLAT
or

CLHLAT

N

Laterality (Dominant Hand)

Valid Entries are:
   “R” – Right
   “L” – Left 
   "N" - none

NOD

Y

Numeric

Refracted object distance at near viewing point (meters)

Valid values 0.20 to 0.60 m

CLNVBNString7Near Vision Behaviour, used for Essilor Varilux X designsMust be 7 alphanumeric characters; for example
CLNVB=HCN7DEV

Numeric


Cape Head Angle

Measured by Visi-Office
Values -10 to +10

_LP


Y



Progression Length (corridor length)

Valid values vary by design
Typically 13, 14, 15, etc., in 1/10 increments

DMNTEYE


N



Dominant Eye

R-right, L-left, or N-none

_CLLAT
or

CLHLAT


N



Laterality (Dominant Hand)

Valid Entries are:
   “R” – Right
   “L” – Left 
   "N" - none

NOD


Y

Numeric


Refracted object distance at near viewing point (meters)

Valid values 0.20 to 0.60 m

CLNVB
NString7Near Vision Behaviour, used for Essilor Varilux X designsMust be 7 alphanumeric characters; for example
CLNVB=HCN7DEV(
CCBLND or _LTLVLOYNumeric2Digital Lenticular Blending

A value between 0 and 10 depending on the digital type.

0-2 for "Essilor", "Crossbows", "Rx-Me", "Rx-PRO" and "A2Vision".

0-10 for all other digital vendors.

CCBOWL or _LTDIAOYNumeric2Digital Lenticular BowlA value between 30 and 90
CLLIFEONString
CLLIFE option for specified digital design(s)Valid values are "Static" or "Active"


This ASCII text file will be generated at the retail site and be sent to the lab from which they are placing their order.  The following is an example of items you can find in an order file (RAW file):

...

R=2547;2547;2548;2548;2549;2550;2550;2551;2552;2553;2553;2554;2556;2557;2557
R=2559;2560;2561;2562;2564;2565;2566;2567;2569;2570;2572;2574;2576;2578;2580
R=2582;2584;2586;2588;2590;2591;2593;2595;2597;2599;2602;2604;2606;2608;2610
R=2612;2614;2616;2618;2619;2620;2623;2625;2628;2631;2634;2637;2639;2637;2630
R=2619;2605;2590;2575;2558;2543;2530;2517;2503;2489;2475;2462;2447;2435;2424
R=2410;2399;2386;2375;2363;2352;2342;2333;2323;2314;2307;2299;2291;2284;2277
R=2272;2266;2261;2255;2250;2246;2242;2239;2236;2233;2233;2230;2229;2229;2229
R=2229;2229;2231;2232;2234;2236;2238;2242;2246;2249;2254;2259;2264;2269;2274
R=2280;2286;2292;2299;2307;2315;2323;2332;2342;2351;2361;2369;2379;2388;2398
R=2408;2417;2428;2439;2450;2460;2471;2482;2493;2505;2516;2527;2538;2549;2560
R=2570;2580;2591;2601;2610;2619;2627;2636;2644;2651;2658;2665;2672;2679;2684
R=2689;2692;2695;2697;2697;2698;2697;2696;2695;2692;2689;2685;2680;2674;2668
R=2660;2653;2643;2635;2627;2618;2610;2601;2593;2584;2575;2566;2557;2546;2537
R=2528;2518;2509;2499;2490;2480;2471;2462;2452;2444;2435;2426;2417;2409;2400
R=2392;2384;2377;2370;2363;2357;2351;2345;2340;2336;2331;2326;2322;2316;2312
R=2306;2302;2297;2293;2290;2286;2283;2280;2277;2274;2272;2268;2266;2263;2261
R=2258;2256;2253;2250;2248;2246;2243;2242;2240;2237;2236;2233;2232;2230;2227
R=2226;2224;2222;2221;2219;2217;2215;2215;2214;2212;2212;2210;2208;2207;2205
R=2205;2203;2201;2200;2198;2196;2194;2194;2192;2191;2191;2190;2191;2190;2191
R=2191;2191;2193;2194;2195;2197;2198;2198;2202;2204;2208;2209;2213;2215;2218
R=2222;2226;2230;2235;2239;2244;2249;2254;2260;2266;2272;2277;2284;2291;2298
R=2306;2314;2323;2332;2340;2348;2357;2368;2377;2387;2394;2405;2414;2424;2434
R=2444;2456;2468;2477;2490;2501;2511;2525;2536;2548;2559;2569;2580;2593;2603
R=2614;2617;2615;2611;2607;2604;2602;2599;2597;2594;2592;2590;2588;2586;2584
R=2581;2579;2578;2576;2574;2572;2570;2568;2566;2564;2562;2561;2560;2558;2557
R=2556;2555;2554;2553;2552;2551;2550;2549;2548;2548;2547;2547;2547;2546;2546
R=2546;2545;2545;2546;2545;2545;2546;2546;2546;2547
EOJ=END OF JOB


Sending Status Requests / Other

(See Appendix 4)

You can make requests from the lab through Rx-Universe; the types of requests that you can make are as follows:
       Request quote (Rx-Invoice and Rx-Connect Modules Required at the Lab)
       Request order status (Rx-Tracker and Rx-Connect Modules Required at the Lab)
       Request to cancel the order
       Request to hold the order
       Request to ship the order

...

Field NameData TypeLengthDescriptionFormat / Valid Values

JOB

String

07

The original Job or PO number of the job that you are inquiring about.


_ACTION

Numeric

01

The type of request you are making.

Valid Entries are:
2 – Request a Quote
     (Rx-Pricing Required)
3 – Request Order Status
     (Rx-Tracker Required)
4 – Request to Cancel
6 – Request to Hold
7 – Request to Ship
     (Rx-Tracker Required)

Receiving Order Status

(See Appendix 4)

Order Status are received after an order is sent or the user can specifically make an order request.  The retail system will have to pick the order status up from the lab.  After an order is processed it creates a file in a folder that is specified in the Rx-Universe Remote Order Processing Options screen + “\” + Retail Account Number.  The file name will consist of the “Job Number”.STA

...

Field NameData TypeLengthDescriptionFormat / Valid Values

_LABID

String

12

The lab number


ACCN

String

08

The retailer’s account number with the lab


JOB

String

21

Job or PO number


_STATUS

Numeric

02

Order Status Code

Valid Entries are:
5 – Cancel, order rejected, request denied (if cancel request sent)
6 – Order quoted
7 – Order in progress (more detail in description)
8 – Order completed
10 – Order Cancelled (if cancel request sent)

_LABSTAT

String

60

Order Status Description

(see above field)

_LABREM

String

30

Lab Remarks

Can occur multiple times

_ESTCOMP

Date

08

Estimated Completion Date

YYYYMMDD

_ESTCOST

Numeric

10

Estimated Cost

99999999.99

_INVNO

Numeric

08

Invoice Number

99999999

 

 

Appendix 1:

_LCODE:

RAW File:

DO=B
_LCODE=C IMAGE TR7BN3;C IMAGE TR7BN3


O/E Rx Screen:


Appendix 2:

_LSTYLE, _MATERIAL, _TINT and _TREAT:

...

DO=B
_LSTYLE=IMAGE;IMAGE
_MATERIAL=C;C
_TREAT=TR7;TR7
_TINT=BN3;BN3


O/E Rx Screen:


Appendix 3:

_TRACE:

RAW File:

_TRACE="FRAME-1"


O/E Rx Screen:

...

Image Added

In the Frame Traces:Image Removed

Image Added

Appendix 4 - Sending and Receiving Order Status:

Lab’s Rx-Universe requirements:

...