MrOrange can communicate with RxUniverseRx-Universe. It is important to understand that the current configuration setup of “MrOrange” may bring some limitations to some Labs.

As it stands the “MrOrange” Trace/blocker combo is the central point of communication to RxUniverseRx-Universe. In other words, the “MrOrange” Edger it is not capable of communication directly to RxUniverse, therefor therefore jobs that have been traced or blocked on any other equipment other then the connected “MrOrange” Trace/blocker combo can not be edged on the “MrOrange” Edger. This also means that any Jobs traced and blocked by the “MrOrange” Tracer/Blocker combo cannot be edged on any other edger then the very same one that it is connected to.

 

Physical Setup

MrOrange can connect to RxUniverse Rx-Universe via RS-232 only, it is not capable of communicating via TCP/IP.

1- From the Tracer/Blocker unit you will need to run a Serial Cable (RS-232) to a computer running RxUniverse Rx-Universe Device sessions.

2- From the Edger to the Tracer/Blocker unit you need to have a RJ45 Crossover cable to connect between the Tracer/Blocker RJ45 Port to the Edger RJ45 Port. The port on the Edger is located under the top tray. 

...

3- To verify the communication between the Tracer/Blocker and Edger you will see a green checkmark on the Top top right Corner Icon

4- Next you need to connect the provide “MrOrange” bar code scanner to the Tracer/Blocker, there should be a second bar code scanner attached to the Edger.

...