Define Block Pieces and Selection Rules

Nucleo/ART blocks have some additional parameters that must be set up in Rx-Universe.  The block and blank together look as follows:

...

When you remove a row in a block selection grid, the minimum radius of the previous row will be changed to match the maximum radius in the current row (to avoid gaps).  When adding a row, however, it is the user's responsibility to ensure that the block pieces are correctly described (named), and that the selection rules are correct for the blocks.  Rx-Universe WILL allow overlap and/or gaps when block pieces are being added.

Select Block Pieces by Diameter

Because ART and Nucleo blocks can be cribbed (the cribbing process actually cribs the block down, as well as the blank), and the block pieces can be re-used, a lab will quickly find itself with many block pieces of different diameters.  To re-use, the blocks can be grouped into "groups" by diameter.  The number of groups and the sizes of each group can be defined by the lab.

...