Zeiss digital designs do use Zeiss pucks – not regular SV blanks – so these Zeiss pucks must be set up in the lab’s inventory, and the blank selection alias should be set up to alias each design to the PUCK items, similar to:

LNAM, LMATID, COLR

The Zeiss calculator uses LNAM, LMATID and COLR to select the correct product to do calculations on.  LNAM is set on the specific lens design, but LMATID and COLOR are set for all designs, in the VCA label table ZEIS.

The lab should ensure the latest values for the ZEIS table, by using the "Web Import" option under "Devices", "VCA Label Table Settings", and updating the ZEIS table:
Image Added

Then, the digital interface to Zeiss must be set to use that ZEIS table, this is done under "Devices", "Device Interface Parms", and then, on the specific setup for the Zeiss calculator:
Image Added

Cribbing

With Zeiss Digital, there are several options which control how cribbing is calculated and handled.

...