Zeiss uses an XML-based web service which LMS systems communicate with.  The lab will be provided with a URL to connect, as well as a lab ID and password.  These settings are unique to each lab and must be set up in the Digital Types entry for the Zeiss calculator.

Zeiss does provide As of summer 2015, Zeiss provides support for base curve requests (BRS) for some all designs, through the web service, so these designs should be set up with the “Use BRS to get BC from DS” option checked.  Generally speaking, the AO and Sola designs support BRS requests, while the Zeiss designs do not.  The LNAM values can be set up in the lens style, as they do not differ by material, coating, or treatment.

Zeiss digital designs do use Zeiss pucks – not regular SV blanks – so these Zeiss pucks must be set up in the lab’s inventory, and the blank selection alias should be set up to alias each design to the PUCK items, similar to:

 

Alternate Interface with Schneider Equipment

If you are using Schneider equipment with the Zeiss designs, you will need to manually create sub-folders in the “Location of SDF files from digital surface” location to allow for machine dependent command files that are returned by the calculator.

Image Removed

 Image Added

The folders are machine dependent and are as follows:

HSC100 for the Schneider HSC 100/101, using example, “DS\ZEISS\SDF\HSC100”

HSCSMT for the Schneider HSC Smart, using example, “DS\ZEISS\SDF\HSCSMT”

HSCMST for the Schneider HSC Master, using example, “DS\ZEISS\SDF\HSCMST”

CCP101 for the Schneider CCP101 polisher, using example, “DS\ZEISS\SDF\CCP101”

CCP102 for the Schneider CCP102 polisher, using example, “DS\ZEISS\SDF\CCP102”

When using Schneider equipment, a user-defined VCA label is used to tell the equipment to look for “technology” files in the above folders. Each different model of device should be configured to look at the appropriate folder, so it gets the correct technology file for the device.

To accommodate the user of either tray number or order number, the _ALTINTR label (used to tell the Schneider equipment to use the alternate interface), can be modified to send the order number as part of the response. As of version 6.45.00, a new option has been added which causes the order number of the job to be appended to the _ALTINTR=1 record sent to the device.  This allows either the tray number or the order number to be scanned on the device, and allows the equipment to find the correct file.  Because this option is not supported by all versions of software on Schneider equipment, it must be activated by checking the appropriate box when use is desired.

Image Added

Verification Ticket

Zeiss requires a verification ticket to be printed, by the lab, for each job.  This ticket can be printed in two ways – either manually from Rx-Universe, by scanning each tray, or automatically when the job is shipped.

...