If not all prism can be blocked, and the generator does not allow GPRVM to be sent for digital jobs, then an error will be raised when the job is requested by the generator, and the job not manufactured.  This will prevent jobs from being manufactured without the correct amount of prism.


Zeiss Digital with Schneider Equipment and Alternate Interface (version 6.44.05)

When using Zeiss Digital with Schneider equipment, for which the alternate interface is to be used, a new option has been added which causes the order number of the job to be appended to the _ALTINTR=1 record sent to the device.  This allows either the tray number or the order number to be scanned on the device, and allows the equipment to find the correct file.  Because this option is not supported by all versions of software on Schneider equipment, it must be activated by checking the appropriate box when use is desired.

Image Added




Devices

Fixed issue where NPD was no longer being sent to devices which requested it for IOT digital jobs (version 6.44.01).

The re-use database wasn't being correctly updated, and correct block records were not being read.  This has been corrected (version 6.44.04).

Modified device interface to use Zeiss digital with Schneider equipment (version 6.44.05).

The device interface has been changed to send GAX as a decimal value, not an integer.  If LAPAX is received, it will be saved and returned to devices when required (version 6.44.06).

...

Support has been added for the Satisloh Micro-Blocker - for complete details, please see Satisloh Micro-Blocker (version 6.45.00).

A new checkbox has been added to the Device Interface Parameters on the Other tab; “Send one eye based on barcode” (version 6.44.08).

 

Work Tickets

A new option has been added to the Surf2 tab of System Settings, to specify that barcodes should be printed for the right and left eyes on the work ticket:
Image Added

This is needed for devices which must request the data for one eye at a time.  When checked, the PCL work ticket will print 3 barcodes in the Conveyor section instead of just 1:
Image Added

When using this option, the appropriate device interface should be set up to expect the one-eye barcode:
Image Added


Reports

The Stock Costing Report was modified to use the standard cost (vendor cost 1) instead of the average cost when determining the value of excess stock (version 6.44.02).

 

Order Entry

The PCL and PCI work tickets have been changed, for uncuts without frame, to print the User ELLH (version 6.44.04). 

...

When auto-attaching a trace to an order, if a CCIRCUM value exists, it will be removed since it resizes the new trace (version 6.44.07).

Databases

A new checkbox option for resizing frame shapes has been added.  On the order entry screen, a new button allows a selected trace to the Device Interface Parameters on the Other tab; “Send one eye based on barcode” (version 6.44.08).be re-sized:
Image Added

When selected, the subsequent window allows the user to specify different sizes for the frame and PD measurements.  The original shape/size is displayed, and the new, re-sized shape/size is displayed in red:
Image Added

 


System Settings

Two new checkboxes have been added to the Surf2 tab; “Use A4 paper for WT” and “Separate barcodes for left and right eyes” (version 6.44.08). 

...