Field Name | Reqd | Chiral | Data Type | Length | Description | Format / Valid Values |
---|---|---|---|---|---|---|
DO | R | Y | String | 01 | Which eye | Valid Values: |
_LSTYLE | C | Y | String | 06 | If _LCODE and UPC are not specified, this field specifies the lab code for the lens style being ordered | |
_MATERIAL | C | Y | String | 02 | If _LCODE and UPC are not specified, this field specifies the lab code for the lens material being ordered | |
_TREAT | C | Y | String | 03 | If _LCODE and UPC are not specified, this field specifies the lab code for the treatment of the lens | This is the Pretreatment that comes already on the lens from the manufacturer. |
_TINT | C | Y | String | 03 | If _LCODE and UPC are not specified, this field specifies the lab code for the tint of the lens | This is the Tint (Color) that comes already on the lens from the manufacturer |
_LCODE | C | Y | String | 02 | Lens Material | Refer to catalogue reference, under the lens section. This is the code from the catalogue You may also use UPC with the UPC translation table to specify materials, lens styles, |
SPH +/- | R | Y | Numeric | 05 | Rx Sphere Power | Range from -39.0 to +49.0 and must be a multiple of 0.125, rounded to 2 |
CYL +/- | O | Y | Numeric | 05 | Rx Cylinder Power | Valid values range from-19.75 to +19.75, in increments of 0.125, rounded to |
AX | C | Y | Integer | 03 | Prescribed Cylinder Axis. | Valid values range from 0 to 180. |
IPD | R | Y | Numeric | 03 | Far PD: The far interpupillary distance for Multifocals and can be entered as | Valid range values: |
NPD | C | Y | Numeric | 03 | Near PD or Vertical Decentration: | Valid range values: For SV-Style lenses, this field represents the distance above or below the datum of the OC. |
OCHT | O | Y | Numeric | 04 | Vertical O.C. height measured from the lower boxes tangent of the frame. | |
ADD | C | Y | Numeric | 04 | The add power of the multifocal segment; required for multifocal lenses | 99.99 |
ADD2 | C | Y | Numeric | 04 | The add power of the upper segment in an occupational lens | 99.99 |
SEGHT | C | Y | Numeric | 03 | Segment Height | Ex: SEGHT=19;19 |
SEGDHT | O | Y | Numeric | 04 | This field is only used for multifocal prescriptions. The field contains the length in millimeters of a vertical line that would be drawn from the top of the segment or fitting cross (if progressive type lens) to the point where the vertical line would cross the frame. The position of the line would be vertically from the distance power location to where this vertical line would cross the frame edge. When the SEGDHT is supplied, the value is used along with a trace pattern, to calculate the value of SEGHT. | Ex: SEGDHT=10.2;10.2 |
PRVM +/- | O | Y | Numeric | 04 | Rx Prism in diopters | Ex: |
PRVA | C | Y | String | 03 | Rx Prism direction | Ex: |
ELLH | O | Y | Numeric | 02 | Elliptical Cribbing | Ex: ELLH=62;62 |
_SUPELLH | O | Y | String | 01 | Suppress Elliptical Cribbing | Valid Values are: |
THNP | O | Y | Numeric | 03 | Requested edge thickness at the thinnest edge | Ex: THNP=1.5;1.5 |
_PRTHIN | O | N | String | 01 | Prism Thinning | Valid Entries Are: |
_ADDON | O | N | String | 06 | Add-on Codes | Codes specified by receiving lab or from catalogue. |
CLASS | O | Y | String String | 03 03 | To force Finished (Stock) or Semi-Finish lenses per eye | Valid Values |
_FORCESF_F | O | Y | String | 01 | To force Semi-Finish or Finished (Stock) lenses on your job | Valid Values: |
_RFRONT | O | Y | String | 04 | Requested Nominal Front Curve | Ex: _RFRONT=0400;0400 |
_RDIA | O | Y | Numeric | 02 | Requested Blank (Lens) Diameter | Ex: _RDIA=76;76 |
_LMFRID | O | Y | String | 04 | Lens Manufacturer | If you want to force Rx-Universe to select a lens from a certain manufacturer |
OPC | O | Y | Numeric | 10 | Lens OPC Code | Select lenses by OPC codes |
SWIDTH | C | Y | Numeric | 02 | Segment Width | Ex:_SWIDTH=28;28 |
SDEPTH | C | Y | Numeric | 02 | Segment Depth of the Intermediate Segment. Required only for Trifocal lenses | Ex:SDEPTH=08;08 |
LNAM | O | Y | String | 23 | VCA Label Translation | |
LTYP | O | Y | String | 23 | VCA Label Translation | |
HBOX | C | O | Numeric | 03 | Horizontal box lens size of the frame. This is the “A” measurement | Valid range of values is from 30.0 to 80.0 mm |
VBOX | C | O | Numeric | 03 | Vertical boxes lens size of the frame. This is the “B” measurement. | Valid range of values is from 15.0 to 60.0 mm |
_EDBOX | C | O | Numeric | 03 | “ED” measurement of the box measurement system. The widest possible | Valid range of values is from 30.0 to 80.0 mm |
DBL | R | N | Numeric | 03 | Distance Between Lenses | Valid range of values is from 7.0 to 30.0 mm |
ETYP | O | N | String | 01 | Type of edge to cut on lens. | Valid Entries are: |
SFTHK | O | N | String | 01 | This field needs to be placed after the “ETYP” field | Y = Safety Thickness |
FTYP | O | N | Numeric | 01 | Frame Type | Valid Entries are: |
_SHAPE | O | N | String | Stored trace in RxUniverse that are saved as shapes (SHAP) names | Rx-Universe will look into the Pattern Database for a Frame Name matching the value of “_SHAPE”, with the Manufacturer of “SHAP”. The VBOX and HBOX fields are checked against the stored shape's values and the _SHAPE trace will be resized accordingly and INV# trace will be created with the resized trace and attached to the received order. | |
_TRACE | O | N | String | 12 | Trace Number | Rx-Universe will look into the Pattern Database for a Frame Name matching |
_CCIRC | O | N | Numeric | 04 | You can specify the actual circumference of the customer’s frame. | Ex: CIRC=138.4 |
_WRAP | O | N | String | 01 | To take advantage of the Wrap Frame Calculation. | Valid Entries are: |
ZTILT | O | N | Numeric | 03 | Panoramic (Wrap) Angle | Valid range of values is from 0 to 30.0 degrees |
PANTO | O | N | Numeric | 03 | Pantoscopic (Angle) Tilt | Valid range of values is from 0 to 30.0 degrees |
BVD | O | N | Numeric | 03 | Vertex Fitting. Back vertex distance, as worn (mm) | Valid range of values is from 5 to 30 mm |
RVD | O | N | Numeric | 03 | Refracted Vertex Distance - Back vertex distance, as refracted (mm) | Valid range of values is from 5 to 30 mm
|
TRCFMT | O | N | Numeric | 01 | Format of frame trace data | Valid Entries are: |
Number | 04 | Number of radii in the trace | ||||
String | 01 | Radius mode identifier | Valid Entries are: | |||
String | 01 | Which eyes are included | Valid Entries are: | |||
ZFMT | O | N | Numeric | 01 | Format of vertical height frame trace data | Valid Entries are: |
Number | 04 | Number of radii in the trace | ||||
String | 01 | Radius mode identifier | E – the radii are evenly spaced | |||
String | 01 | Which eyes are included | R – Right | |||
R | C | N | Numeric | 05 | Radius Data | Separate values for this field by a semi-colon “;” such as: |
A | C | N | Numeric | 05 | Angle data for radius data (angular locations of trace radii expressed | Separate values for this field by a semi-colon “;” such as: |
Z | C | N | Numeric | 05 | Radius Data | Separate values for this field by a semi-colon “;” such as: |
CTHICK | O | Y | Numeric | 05 | Center thickness - used only if a specific center thickness is desired for the lens. This can | CTHICK=2.3;2.3 |
UPC | O | Y | Numeric | 12 | This is a translation code that can be used with the UPC translation file to specify either lens style, material, tint and treatment, or an addon code. This allows a third party system to send one code that can be translated on the Rx-Universe side into the lab's codes for the lens product. |
...