Information that is sent back from Rx-Universe will be located in this directory, which is usually called “OMICSRX” – this is usually a subfolder below the default “RXUNIVERSE” folder on the lab’s server.  For example “C:\RXUNIVERSE\OMICSRX”.  Under this folder there is a folder for each customer created by Rx-Universe automatically, the folder name will be the account number, this is where the retail site will have to pick up the status files. 

...

If sent, the values will be used if applicable for the lens design ordered.

Field NameReqdChiralData TypeLengthDescriptionFormat / Valid Values

CLINIT

 

N

String

 

Wearer’s Initials

up to 4 alphanumeric characters

CLHT

 

N

Numeric

 

Client Height in meters

 

HEADK

 

N

Numeric

 

Head Eye Coefficient

Measured by Visi-Office
Values 0 to 0.99

HEADS

 

N

Numeric

 

Stability Coefficient

Measured by Visi-Office
Valid values 0 to 0.15

_NVI

 

Y

Numeric

 

Near Vision Inset

Inset of the near vision segment relative
to the distance reference point
Valid values are 0 to 7.0 mm

NWD

 

N

Numeric

 

Near Working Distance

Working object distance at near viewing
point (in meters).

ERCD

 

Y

Numeric

 

Eye Rotation Center Distance

Measured by Visi-Office
Values 16.0 to 38.0 mm

CAPE

 

Y

Numeric

 

Cape Head Angle

Measured by Visi-Office
Values -10 to +10

_LP

 

Y

 

 

Progression Length (corridor length)

Valid values vary by design
Typically 13, 14, 15, etc., in 1/10 increments

DMNTEYE

 

N

 

 

Dominant Eye

R-right, L-left, or N-none

_CLLAT
or

CLHLAT

 

N

 

 

Laterality (Dominant Hand)

Valid Entries are:
   “R” – Right
   “L” – Left 
   "N" - none

NOD

 

Y

Numeric

 

Refracted object distance at near viewing point (meters)

Valid values 0.20 to 0.60 m

...