  • generator prism will usually be set, to minimize prism needing to be blocked
  • the tape thickness should be set to 0 (since tape is not used with this blocker)
  • the ART blocker flag MUST be set - this causes the interface to accept uploaded data after blocking

On the Digital tab, you should NOT if you are running Rx-Universe version 7.35.00 or earlier, you SHOULD have the option to save new block info checked - if not checked, the ART Blocker switch (above) handles the fields that are proper for the ART:AVAL uploaded from the blocker will not be saved.  In version 7.36.00 or later, this is not required (the ART blocker switch handles it).

Settings on the blocker itself

...

Settings for the generator interface

If the ART you are running Rx-Universe version 7.35.00 or earlier, and using an ART-M, the blocker does not upload BLKD and RNGH information, and .  If the lab uses ONLY ART blocking, you will need to configure the generator interface to set these values.  Do this, on the generator configuration, VCA Over-rides tab, as follows:

Note this is NOT necessary for Rx-Universe version 7.36.00 and later.